m+Medelevator.RU
← Поиск публикаций
Thrombosis research · 2020

Heparin-induced thrombocytopenia: Diagnostic challenges in intensive care patients especially with extracorporeal circulation.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Althaus Karina, Straub Andreas, Häberle Helene, Rosenberger Peter, Hidiatov Oleg, Hammer Stefanie, Nowak-Harnau Stefanie, Enkel Sigrid, Riessen Reimer, Bakchoul Tamam

Аннотация

BACKGROUND: Heparin-induced thrombocytopenia (HIT) is a serious drug induced reaction that may be associated with life threatening complications. Platelet-activating antibodies directed against platelet factor 4 (PF4)/heparin complexes cause the disease. The diagnosis of HIT is challenging, as thrombocytopenia is a frequent finding in intensive care (ICU) patient population, especially during extracorporeal membrane oxygenation.

OBJECTIVE: To investigate the performance of a diagnostic algorithm for HIT in ICU patients.

METHODS: ICU patients who developed thrombocytopenia or thrombosis under heparin treatment were included in this study. The pretest probability for HIT was estimated using the 4Ts-score and patient's sera were tested using two rapid immunoassays (RA) LFI-HIT and PaGIA (from Milenia Biotec and DiaMed), and within 72 h using the IgG enzyme immunoassay (EIA) from Hyphen and the heparin induced platelet activation assay (HIPA).

RESULTS: 392 consecutive ICU patients with suspected HIT were enrolled in this study, of whom 83/392 (21.2%) patients had extracorporeal circulation. Sera from 120/392 (30.6%) and 98/392 (25.0%) patients revealed positive results in RA and IgG EIA, respectively. The HIPA test revealed heparin-dependent platelet activation in a total of 15/392 (3.8%) ICU patients (3 medical and 12 surgical patients). In addition, sera from 7 patients revealed indeterminate HIPA results, of whom 2 patients had a clinical course compatible with HIT.

CONCLUSIONS: Data from our study confirm the high frequency of IgG PF4/heparin antibodies in ICU patients under unfractionated heparin and shows that the combination of 4Ts-score and RA does not reduce the laboratory overinvestigation for HIT in these patients.