MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.thromres.2020.01.026

Медицинская библиотека · Thrombosis research · 2020

Heparin-induced thrombocytopenia: Diagnostic challenges in intensive care patients especially with extracorporeal circulation.

Althaus Karina, Straub Andreas, Häberle Helene, Rosenberger Peter, Hidiatov Oleg, Hammer Stefanie, Nowak-Harnau Stefanie, Enkel Sigrid, Riessen Reimer, Bakchoul Tamam

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Heparin-induced thrombocytopenia (HIT) is a serious drug induced reaction that may be associated with life threatening complications. Platelet-activating antibodies directed against platelet factor 4 (PF4)/heparin complexes cause the disease. The diagnosis of HIT is challenging, as thrombocytopenia is a frequent finding in intensive care (ICU) patient population, especially during extracorporeal membrane oxygenation.

OBJECTIVE

To investigate the performance of a diagnostic algorithm for HIT in ICU patients.

METHODS

ICU patients who developed thrombocytopenia or thrombosis under heparin treatment were included in this study. The pretest probability for HIT was estimated using the 4Ts-score and patient's sera were tested using two rapid immunoassays (RA) LFI-HIT and PaGIA (from Milenia Biotec and DiaMed), and within 72 h using the IgG enzyme immunoassay (EIA) from Hyphen and the heparin induced platelet activation assay (HIPA).

RESULTS

392 consecutive ICU patients with suspected HIT were enrolled in this study, of whom 83/392 (21.2%) patients had extracorporeal circulation. Sera from 120/392 (30.6%) and 98/392 (25.0%) patients revealed positive results in RA and IgG EIA, respectively. The HIPA test revealed heparin-dependent platelet activation in a total of 15/392 (3.8%) ICU patients (3 medical and 12 surgical patients). In addition, sera from 7 patients revealed indeterminate HIPA results, of whom 2 patients had a clinical course compatible with HIT.

CONCLUSIONS

Data from our study confirm the high frequency of IgG PF4/heparin antibodies in ICU patients under unfractionated heparin and shows that the combination of 4Ts-score and RA does not reduce the laboratory overinvestigation for HIT in these patients.

Для цитирования: Althaus Karina, Straub Andreas, Häberle Helene, Rosenberger Peter, Hidiatov Oleg, Hammer Stefanie, Nowak-Harnau Stefanie, Enkel Sigrid, Riessen Reimer, Bakchoul Tamam. Heparin-induced thrombocytopenia: Diagnostic challenges in intensive care patients especially with extracorporeal circulation.. Thrombosis research. 2020. DOI: 10.1016/j.thromres.2020.01.026.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.