American heart journal · 2019
Transesophageal echocardiography complications associated with interventional cardiology procedures.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Freitas-Ferraz Afonso B, Rodés-Cabau Josep, Junquera Vega Lucía, Beaudoin Jonathan, O'Connor Kim, Turgeon Pierre Yves, Paradis Jean-Michel, Ferreira-Neto Alfredo, Asmarats Lluis, Champagne Jean, O'Hara Gilles, Bernier Mathieu
Аннотация
BACKGROUND: Although there have been several reports documenting complications related with transesophageal echocardiography (TEE) manipulation following cardiac surgery, there is a paucity of data regarding the safety of TEE used to guide catheter-based interventions. The aim of this study was to determine the prevalence, types and risk factors of complications associated with procedures requiring active TEE guidance.
METHODS: This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, n = 1037) and high-risk (Mitraclip, LAAO and PVLC, n = 212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications.
RESULTS: The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (P < .001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, P = .008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (OR = 1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, P < .001).
CONCLUSION: The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.
METHODS: This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, n = 1037) and high-risk (Mitraclip, LAAO and PVLC, n = 212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications.
RESULTS: The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (P < .001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, P = .008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (OR = 1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, P < .001).
CONCLUSION: The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.
Предметные рубрики MeSH
AgedAged, 80 and overAtrial AppendageBlood TransfusionCardiac CatheterizationDeglutition DisordersEchocardiography, TransesophagealEsophageal PerforationEsophagusFemaleGastrointestinal HemorrhageHumansLacerationsMaleMitral ValvePostoperative ComplicationsRetrospective StudiesSurgery, Computer-AssistedTime FactorsTranscatheter Aortic Valve Replacement