Transesophageal echocardiography complications associated with interventional cardiology procedures.
Аннотация
BACKGROUND
Although there have been several reports documenting complications related with transesophageal echocardiography (TEE) manipulation following cardiac surgery, there is a paucity of data regarding the safety of TEE used to guide catheter-based interventions. The aim of this study was to determine the prevalence, types and risk factors of complications associated with procedures requiring active TEE guidance.
METHODS
This study included 1249 consecutive patients undergoing either transcatheter aortic valve implantation (TAVI), Mitraclip, left atrial appendage occlusion (LAAO) or paravalvular leak closure (PVLC). Patients were divided into 2 cohorts based on the degree of probe manipulation required to guide the procedure and the risk of developing a TEE-related complication: low-risk (TAVI, n = 1037) and high-risk (Mitraclip, LAAO and PVLC, n = 212). Patients were further analyzed according to the occurrence of major and minor TEE-related complications.
RESULTS
The overall incidence of TEE-related complications was 0.9% in the TAVI group and 6.1% in the rest of the cohort (P < .001). Patients in the high-risk cohort had also a higher incidence of major-complications (2.8% vs 0.6%, P = .008), and factors associated with an increased risk were being underweight, having a prior history of gastrointestinal bleeding and the use of chronic steroids/immunosuppressive medications. Procedural time under TEE-manipulation was longer in patients exhibiting complications and was an independent predictor of major complications (OR = 1.13, 95% CI 1.01-1.25, for each 10 minutes increments in imaging time). Patients with major complications undergoing Mitraclip had the longest median time under TEE-manipulation (297 minutes) and a risk of developing a major-complication that was 10.64 times higher than the rest of the cohort (95% CI 3.30-34.29, P < .001).
CONCLUSION
The prevalence of TEE-related complications associated with interventional procedures is higher than previously reported. Undergoing a prolonged procedure, particularly in the setting of Mitraclip, was the main factor linked to TEE-related complications.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.