MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.15272

Медицинская библиотека · Transfusion · 2019

The successful implementation of an automated institution-wide assessment of hemoglobin and ABO typing to dynamically estimate red blood cell inventory requirements.

Quinn Jason, Campbell Clinton, Gomez Alwyn, Kumar-Misir Andrew, Watson Stephanie, Liwski Daniel, Covello Thomas, Tennankore Karthik K, Chisholm Natalie, Sadek Irene, Cheng Calvino

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Blood bank inventories must balance adequate supply with minimal outdate rates. The day-to-day practice of ordering red blood cell (RBC) inventory usually involves manually comparing current inventory levels with predetermined thresholds calculated from historical usage and ordering the difference. To date, there have been no published methods for ordering RBC inventory based on laboratory characteristics of admitted patients.

STUDY DESIGN AND

METHODS

We designed and implemented a blood ordering algorithm to provide a more accurate measure of predicted RBC utilization in our institution. Cerner Command Language (Cerner Millennium) was used to extract and combine historical RBC unit usage, current inventory levels, and system-wide hematology values and blood groups. This report contains a suggested order based on current inventory, historical inventory data, ABO group, and the current "anemia index" for the institution.

RESULTS

The mean daily total RBC inventory was significantly reduced after implementation (401.7 units vs. 309.0 units, p < 0.05). There was a significant reduction in monthly RBC outdates in this period (19.1 vs. 8.1, p < 0.05). The age of RBCs at time of transfusion was reduced as well.

CONCLUSION

We developed a novel algorithm that automatically generates a suggested RBC inventory order using real-time hospital-wide survey of patient ABO typing, hematology values, and historical data. After implementation of the algorithm we demonstrated a significant reduction in daily inventory levels and RBC outdate rates.

Для цитирования: Quinn Jason, Campbell Clinton, Gomez Alwyn, Kumar-Misir Andrew, Watson Stephanie, Liwski Daniel, Covello Thomas, Tennankore Karthik K, Chisholm Natalie, Sadek Irene, Cheng Calvino. The successful implementation of an automated institution-wide assessment of hemoglobin and ABO typing to dynamically estimate red blood cell inventory requirements.. Transfusion. 2019. DOI: 10.1111/trf.15272.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.