m+Medelevator.RU
← Поиск публикаций
Annales de biologie clinique · 2019

[Factor IX assays in treated hemophilia B patients].

СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pouplard Claire, Jeanpierre Emmanuelle, Lasne Dominique, Le Cam Duchez Véronique, Eschwege Valérie, Flaujac Claire, Galinat Hubert, Harzallah Ines, Proulle Valérie, Smahi Motalib, Sobas Frédéric, Ternisien Catherine, Toulon Pierre, Voisin Sophie, Nougier Christophe, groupe d’études de la biologie des maladies hémorragiques du Groupe français d’études de l’hémostase et la thrombose

Аннотация

Replacement therapy with plasma-derived or recombinant FIX (pdFIX or rFIX) concentrates is the standard of treatment in patients with hemophilia B. The method predominantly used for measuring factor IX (FIX:C) levels is the one-stage clotting assay (OSA) but this method depends on the activated partial thromboplastin time (APTT) reagent and the coagulation analyzer used, and wide variations in the measurements of FIX recovery have been reported with some factor concentrates. The French study group on the biology of hemorrhagic diseases (a collaborative group of the GFHT and MHEMO network), presents a review of the literature and proposals for the monitoring of FIX:C levels in treated hemophilia B patients. The use of OSA calibrated with a plasma reference tested against the current FIX WHO International Standard is recommended for the monitoring of patients treated with pdFIX or rFIX. Chromogenic substrate assays (CSA) are adequate for the monitoring of patients treated with Rixubis®, but data available for Benefix® are currently too limited. For extended half-life rFIX (EHL-rFIX), large discordances in the FIX:C levels measured were evidenced, depending on the method and reagents used. Great attention is therefore required for measuring FIX:C levels by OSA in patients substituted by EHL-rFIX. Commercial kits for CSA are not equivalent, and although potentially useful, they are not validated for all EHL-rFIX. Most of recent studies reported data obtained with spiked plasmas, which deserve to be confirmed on plasma samples collected in treated patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты