MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41746-026-02914-w

Медицинская библиотека · NPJ digital medicine · 2026

Zero burden multi night monitoring with AI enabled technology reduces obstructive sleep apnea misdiagnosis.

Lechat Bastien, Proctor Simon, Manners Jack, Loffler Kelly A, Leviton Alison, Toson Barbara, Vena Daniel, Vakulin Andrew, Fitton Josh, Adams Robert J, Mukherjee Sutapa, Eckert Danny J

СтатьяПеревод в очереди

Аннотация

Multi-night measurement of obstructive sleep apnea (OSA) using AI-enabled technologies could reduce misdiagnosis rates from night-to-night variation. However, prospective feasibility and effectiveness of multi-night assessment in clinical populations remains uninvestigated. In this study, 100 people with suspected OSA were recruited to receive an under-the-mattress Withings Sleep Analyzer (WSA) to quantify in-home sleep for 3 months alongside single-night polysomnography. The primary outcome was feasibility of novel technology to estimate the apnea-hypopnea-index (AHI), defined as ≥14 nights of AHI recordings within the first month. Secondary outcomes included diagnostic classification of moderate-to-severe OSA (AHI ≥ 15 events/h). 92 participants (53±15yo; BMI = 31 ± 7 kg/m2; 48 females) were included in the final analyses. Eighty-five (92%) had ≥14 nights of valid AHI measurements in the first monitoring month. WSA had specificity of 85% and sensitivity of 77%, and overall F1-score of 80% to detect OSA versus polysomnography. Participants with OSA on WSA but not polysomnography had higher night-to-night variability in OSA severity, and many had minimal supine sleep and short sleep duration during polysomnography (-97 [-183, -11]min, p value = 0.027). Multi-night zero-burden AI monitoring of OSA is feasible and could identify patients at risk of single-night polysomnography misdiagnosis, including those with high night-to-night variability, short sleep, and minimal supine sleep during polysomnography.

Для цитирования: Lechat Bastien, Proctor Simon, Manners Jack, Loffler Kelly A, Leviton Alison, Toson Barbara, Vena Daniel, Vakulin Andrew, Fitton Josh, Adams Robert J, Mukherjee Sutapa, Eckert Danny J. Zero burden multi night monitoring with AI enabled technology reduces obstructive sleep apnea misdiagnosis.. NPJ digital medicine. 2026. DOI: 10.1038/s41746-026-02914-w.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.