MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.phro.2026.101011

Медицинская библиотека · Physics and imaging in radiation oncology · 2026

Transformer-based cardiac substructure segmentation from contrast and non-contrast computed tomography for radiotherapy planning.

Rangnekar Aneesh, Mankuzhy Nikhil, Willmann Jonas, Seo Choi Chloe Min, Wu Abraham, Thor Maria, Rimner Andreas, Veeraraghavan Harini

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: Accurate segmentation of cardiac substructures on computed tomography (CT) scans is essential for radiotherapy planning. This study evaluated whether pretrained transformers enabled data-efficient training using a fixed architecture with balanced curriculum learning while achieving robust generalization to imaging and patient variations.

MATERIALS AND

METHODS

A hybrid pretrained transformer-convolutional network, self-distilled masked image transformer (SMIT), was fine-tuned using lung cancer patient scans (Cohort I, training N = 180) and tested on held-out Cohort I lung cancer scans (testing N = 60) and breast cancer scans (Cohort II, N = 65). Two configurations were evaluated: SMIT-Balanced (32 contrast-enhanced CTs, 32 non-contrast CTs) and SMIT-Oracle (180 CTs). Performance was compared with nnU-Net and TotalSegmentator. Segmentation accuracy was assessed primarily using the 95th percentile Hausdorff distance (HD95), along with radiation dose and overlap-based metrics as secondary endpoints.

RESULTS

SMIT-Balanced approached SMIT-Oracle performance despite using 64% fewer training scans, with mean HD95 of 6.6 versus 5.4 mm in Cohort I and 10.0 versus 9.4 mm in Cohort II. On the Cohort I held-out test set, SMIT-Balanced mean HD95 was within 1.0 mm of nnU-Net. Cross-cohort testing showed larger accuracy degradation with nnU-Net than SMIT-Balanced (62% versus 50%, absolute change 4.5 mm versus 3.4 mm). Dose metrics derived from SMIT-Balanced were equivalent to manual delineations.

CONCLUSIONS

Balanced curriculum training reduced labeled data requirements within the SMIT architecture. SMIT-Balanced was comparable to nnU-Net on Cohort I held-out data and showed smaller cross-cohort HD95 degradation.

Для цитирования: Rangnekar Aneesh, Mankuzhy Nikhil, Willmann Jonas, Seo Choi Chloe Min, Wu Abraham, Thor Maria, Rimner Andreas, Veeraraghavan Harini. Transformer-based cardiac substructure segmentation from contrast and non-contrast computed tomography for radiotherapy planning.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.101011.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.