MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1213/xaa.0000000000000735

Медицинская библиотека · A&A practice · 2018

Transfusion-Associated Circulatory Overload as a Result of Plasma Transfusion to Correct International Normalized Ratio Before an Invasive Procedure: A Case Report.

Cahill Christine M, Blumberg Neil, Refaai Majed A

Клинический случайСтатьяПеревод в очереди

Аннотация

Plasma transfusion is commonly used to correct elevated international normalized ratio (INR) before invasive procedures. A 54-year-old woman presented to the emergency department with abdominal pain. Workup revealed Streptococcus pneumoniae peritonitis. Her hospitalization was complicated by respiratory failure, fluid overload, atrial fibrillation, and acute kidney injury. Patient underwent 2 paracentesis (9 L removed). Four units of plasma were transfused to correct an INR of 3.0 (goal 1.5) for a transjugular intrahepatic portosystemic shunt procedure. INR remained at 1.9, and she developed acute pulmonary edema and died within 24 hours. Prothrombin complex concentrates may have been a more appropriate treatment option in this case.

Для цитирования: Cahill Christine M, Blumberg Neil, Refaai Majed A. Transfusion-Associated Circulatory Overload as a Result of Plasma Transfusion to Correct International Normalized Ratio Before an Invasive Procedure: A Case Report.. A&A practice. 2018. DOI: 10.1213/xaa.0000000000000735.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.