m+Medelevator.RU
← Поиск публикаций
Thrombosis and haemostasis · 2017

Diagnostic Accuracy of a Novel Chromogenic Direct Thrombin Inhibitor Assay: Clinical Experiences for Dabigatran Monitoring.

СтатьяНаблюдательное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Poli Sven, Härtig Florian, Spencer Charlotte, Ebner Matthias, Birschmann Ingvild, Kuhn Joachim, Faix Susanne, Ziemann Ulf, Häring Hans-Ulrich, Lehmann Rainer, Peter Andreas, Hörber Sebastian

Аннотация

Background Direct oral anticoagulants (DOACs) are increasingly replacing vitamin K antagonists (VKA) for clinical indications requiring long-term oral anticoagulation. In contrast to VKA, treatment with DOAC including dabigatran—the only direct thrombin inhibitor amongst them—does not require therapeutic drug monitoring. However, in case of treatment complications (e.g., major haemorrhage) and conditions requiring urgent surgery or thrombolytic therapy, information about actual DOAC plasma levels is needed to guide treatment decisions. Due to short reagent stability, limited accuracy at low dabigatran levels and high heparin sensitivity, the applicability of the widely used Hemoclot thrombin inhibitor (HTI) coagulation assay is limited in the emergency setting. Methods Dabigatran concentrations of 288 citrated plasma samples taken from 48 dabigatran-treated patients with drug concentrations of up to 300 ng/mL were measured with the chromogenic anti-IIa Biophen direct thrombin inhibitor (BDTI) assay and results compared with HTI using ultra performance liquid chromatography—tandem mass spectrometry as the reference method for measuring dabigatran plasma concentrations. Results BDTI results showed a very strong correlation with dabigatran concentrations (r = 0.965, p < 0.0001) as well as a low intra- and inter-assay variation of <5%. Compared with HTI, BDTI provides an improved on-board reagent stability of 72 hours, rapid turnaround times comparable to routine coagulation assays, high accuracy at low drug levels and reduced heparin sensitivity. Conclusion The BDTI is an ideal coagulation assay for the around-the-clock determination of dabigatran plasma levels in clinical routine including emergency situations.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты