Clustering of technological attitudes and reasons for device (non-)uptake among Dutch people with type 1 diabetes, family members and health professionals.
Аннотация
BACKGROUND
Pump and sensor technology contributes to glucose management and quality of life for people with type 1 diabetes (PWD). However, not everyone uses these technologies. This commonly relates to technological attitudes, experiences and expectations. Also, parents and partners (P/P) and healthcare providers (HCPs) may impactful decision-making. Clustering of attitudes towards, experiences with, and expectations of diabetes technology into 'subgroups' may inform meaningful interventions to support device start and continuation in the era of advanced technologies.
AIM: To determine how personal reasons for device non-uptake cluster together into subgroups.
METHODS
A survey was conducted among PWD aged 12+ years (n = 219), P/P (18+, n = 55) and HCPs (n = 118) in Dutch health care. K-means cluster analyses were based on attitudes towards technology (all groups) and reasons for device non-uptake (PWD&P/P) or technological readiness (HCPs). Cluster validation examined cluster differences in demographics, glucometrics and professional characteristics (ANOVAs, X2-tests). Data were combined to create subgroups per sample.
RESULTS
Multiple subgroups were created per sample. Larger subgroups of each sample included positive technological attitudes (31%-67%). The smallest subgroups (PWD: 9%, P/P: 32%) included multiple concerns and insulin pen use. A third subgroup of PWD focused on the burden of device wear (31%). Two subgroups of HCPs had more negative attitudes towards technology, differing mostly in technology readiness (15%-20%), while the fourth had positive attitudes, but also felt less ready.
CONCLUSION
Most participants reported positive attitudes and experiences. Technological concerns clustered together in general or focused on device wear, necessitating general as well as wear-specific technology support. HCPs could benefit from support that facilitates technological readiness.