MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1386-6532(00)00096-2

Медицинская библиотека · Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology · 2000

Evaluation of two commercially available immunoassays for the detection of hantavirus antibodies in serum samples.

Koraka P, Avsic-Zupanc T, Osterhaus A D, Groen J

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

hantaviruses are members of the family Bunyaviridae and the spectrum of clinical symptoms in humans may vary from sub-clinical to severe haemorrhagic fever with renal syndrome (HFRS) or pulmonary syndrome (HPS). Several serotypes have been described from which at least five are pathogenic to humans. Each serotype has a different animal reservoir and geographical distribution. In the acute phase of the disease the clinical diagnosis may be confirmed by serology or by polymerase-chain reaction (PCR).

OBJECTIVE

to evaluate two commercially available immunoassays using sera from hantavirus suspected and non-hantavirus patients: an enzyme immunoassay (EIA) developed by MRL Diagnostics, for the detection of immunoglobulins M (IgM) and G (IgG) against several hantavirus serotypes and an indirect immunofluorescence assay (IFA) from Progen, based on slides coated with Hantaan virus (HNTV) and Puumala virus (PUUV), infected cells.

STUDY

DESIGN

a total of 145 serum samples were used for this study. The serum panel included serum samples from patients suspected of mild (n=91), severe (n=10) HFRS and patients with other viral infections (n=44).

RESULTS

the agreement between the MRL EIA and the Progen IFA for the detection of IgM and IgG serum antibodies ranged from 87 to 91%, respectively. In the non-hantavirus group one out of 44 samples was positive by the Progen HNTV IgM IFA, none in the Progen PUUV IFA and two samples in the MRL IgM EIA, resulting in specificities of 98, 100 and 95%, respectively. The sensitivities and specificities of the MRL EIAs compared to the Progen overall PUUV and HNTV IFAs were 90 and 91% for IgM, respectively, and 96% for IgG in both immunoassays.

CONCLUSIONS

the MRL EIA proved to be relatively sensitive and specific assay for the serological diagnosis of mild and severe HFRS.

Для цитирования: Koraka P, Avsic-Zupanc T, Osterhaus A D, Groen J. Evaluation of two commercially available immunoassays for the detection of hantavirus antibodies in serum samples.. Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology. 2000. DOI: 10.1016/s1386-6532(00)00096-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.