MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0020-1383(17)30657-5

Медицинская библиотека · Injury · 2017

Blood loss in trochanteric fractures: multivariate analysis comparing dynamic hip screw and Gamma nail.

Ronga Mario, Bonzini Daniele, Valoroso Marco, La Barbera Giuseppe, Tamini Jacopo, Cherubino Mario, Cherubino Paolo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

INTRODUCTION

Anaemia in patients with trochanteric fracture is associated with increased morbidity and mortality and it is an independent risk factor for functional mobility of patients. Several authors have reported the blood loss following operative treatment comparing different fixation systems but few authors have evaluated many associated variables that could influence the perioperative blood loss.

PURPOSE: To evaluate the blood loss in patients that had their trochanteric fracture stabilized with dynamic hip screw (DHS) or Gamma nail. Multivariate analysis of different variables that can influence blood loss was carried out (type of fracture, antiaggregant or anticoagulant therapy, time to surgery). The hypothesis was that there is no difference in terms of blood loss in patients with trochanteric fracture treated with DHS or Gamma nail considering all these variables.

MATERIALS &

METHODS

Perioperative blood loss was evaluated in 417 consecutive patients treated for trochanteric fracture with DHS or Gamma nail between January 2010 and March 2013. The perioperative blood loss was calculated using the Lisander formula modified by Foss-Kehlet based on pre- and post-operative haemoglobin values and transfusion rates. Univariate and multivariate analysis were performed integrating the following variables: type of fracture (A1 vs A2), antiaggregant/anticoagulant therapy vs no therapy, time to surgery (<24 vs >24 hours from trauma), type of implant (DHS vs Gamma nail).

RESULTS

A significant blood loss (p <0.05) was observed between A1 and A2 fracture types (1247ml vs 1796.7ml), antiaggregant/anticoagulant therapy and no therapy (1592.7ml vs 1470.2ml), time-to-surgery <24 and >24 hours from trauma (1584.4ml vs 1323.9ml), DHS and Gamma nail (894.7ml vs 1720.6ml). At multivariate analysis, in the A1 fracture groups the DHS showed a significant lower blood loss compared to Gamma nail (p < 0.05).

CONCLUSIONS

According to the perioperative blood loss, DHS should be used in A1 fractures while Gamma nail can be taking in account for the unstable A2 fractures.

Для цитирования: Ronga Mario, Bonzini Daniele, Valoroso Marco, La Barbera Giuseppe, Tamini Jacopo, Cherubino Mario, Cherubino Paolo. Blood loss in trochanteric fractures: multivariate analysis comparing dynamic hip screw and Gamma nail.. Injury. 2017. DOI: 10.1016/s0020-1383(17)30657-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.