Successful ABO-Incompatible Renal Transplantation: Blood Group A1B Donor Into A2B Recipient With Anti-A1 Isoagglutinins.
Аннотация
OBJECTIVES
Transplantation of the blood group A2B in a recipient was successfully performed in the setting of receiving a deceased donor kidney from an "incompatible" A1B donor.
METHODS
The donor and recipient were both typed for ABO blood group, including ABO genotyping. The donor and recipient were tested for ABO, non-ABO, and human leukocyte antigen (HLA) antibodies. The donor and recipient were typed for HLA antigens, including T- and B-flow cytometry crossmatch tests.
RESULTS
The recipient's RBCs were negative with A1 lectin, and immunoglobulin G anti-A1 was demonstrated in the recipient's plasma. The donor-recipient pair was a four-antigen HLA mismatch, but final T- and B-flow cytometry crossmatch tests were compatible. The transplant procedure was uneventful; the patient experienced immediate graft function with no episodes of rejection or readmissions more than 2 years later.
CONCLUSIONS
It may be safe to transplant across the A1/A2 blood group AB mismatch barrier in the setting of low titer anti-A1 isoagglutinins without the need for pretransplant desensitization even if the antibody produced reacts with anti-human globulin.