m+Medelevator.RU
← Поиск публикаций
The American journal of hospice & palliative care · 2026

Testing Near-Field Radio-Frequency Sensors to Predict Respiratory Distress in Patients Living With Dementia: A Pilot Feasibility and Acceptability Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Gangwar Kapil, Park Taeyoung, Krishnan Jamuna, Hayward Bradley, Conroy Thomas Bradley, Toliver Micah Denzel, Joasil Shanyna, Yu Elaine, Fortune Chnidcar, Smith McKenzie, Liao Vanessa, Kan Edwin Chihchuan, Phongtankuel Veerawat

Аннотация

BackgroundPeople living with dementia (PLWD) with advanced illness are prone to respiratory distress yet often cannot self-report dyspnea, delaying recognition and treatment. Near-field radio-frequency (NFRF) sensors offer touchless, covert cardiopulmonary monitoring that may be better tolerated than tethered devices.ObjectivesTo assess the feasibility and acceptability of NFRF bed sensor for home monitoring of PLWD and to estimate machine-learning (ML) performance for detecting respiratory distress.MethodsIn a 48-hour pilot study, PLWD were recruited from a geriatrics practice. A lab-designed NFRF bed sensor recorded cardiopulmonary waveforms. Recorded video enabled minute-level Respiratory Distress Observation Scale scoring as reference. Feasibility outcomes included adverse events, acceptability, and percentage of usable data. ML classifiers (eg, random forest, k-nearest neighbors) were evaluated using 5-fold cross-validation, and class imbalance was addressed through data augmentation.ResultsTen patient-legally authorized representative dyads were enrolled. No adverse events were reported, and no participants intentionally removed the sensor. Usable data averaged 52% (range 34-68%). Caregivers reported minimal burden and no patient distress. With augmented data, the random forest performed best, achieving 74.6% sensitivity and 95.5% specificity in detecting RDOS scores.ConclusionsNFRF bed sensors were feasible and acceptable to implement in the home setting with PLWD, with promising ML-based detection of respiratory distress. Larger, longer studies with a broader range of RDOS severity are needed to validate performance and refine deployment. As this technology develops and matures, it could provide a method for non-invasive continuous monitoring to detect respiratory distress in PLWD in palliative care settings.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты