MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12891-025-08846-y

Медицинская библиотека · BMC musculoskeletal disorders · 2025

Automated radiographic assessment of lower limb alignment using deep learning in a data-constrained clinical setting.

Häfliger Luca, Cina Andrea, Leuthard Louis, Rüdiger Hannes A, Stadelmann Vincent A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

A model using stacked hourglass neural network modules was developed for automated lower limb alignment measurements in full-leg frontal radiographs. The goal was to assess whether high accuracy could be achieved with training on relatively small datasets, a common constraint in clinical research.

METHODS

The model first identifies joints regions of interest (ROIs), then detects anatomical landmarks for alignment measurement within each ROI. 112 bilateral radiographs (216 annotated single-leg images) were used for training and validation, 99 (186 legs) as internal test set, and 25 (49) as external test set. Performance metrics included intraclass correlation coefficient (ICCs) and mean absolute error (MAE).

RESULTS

The model achieved excellent agreement (ICCs > 0.9) with manual annotations for all alignment parameters, except for the joint line convergence angle (ICC < 0.5), which also showed poor agreement between human readers (0.73).

CONCLUSION

The proposed approach demonstrates high accuracy and reliability for automated lower limb alignment assessment, offering a robust solution for clinical research with limited annotated datasets.

Для цитирования: Häfliger Luca, Cina Andrea, Leuthard Louis, Rüdiger Hannes A, Stadelmann Vincent A. Automated radiographic assessment of lower limb alignment using deep learning in a data-constrained clinical setting.. BMC musculoskeletal disorders. 2025. DOI: 10.1186/s12891-025-08846-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.