Journal of veterinary diagnostic investigation : official publication of the American Association of Veterinary Laboratory Diagnosticians, Inc · 2023

Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving clopidogrel.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kornya Matthew R, Abrams-Ogg Anthony C G, Blois Shauna L, Wood R Darren

Аннотация

The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may also report the calculated platelet function measurement primary hemostasis components, PHC1 and PHC2. These incorporate the measured total volume (TV) of blood aspirated and the initial flow rate (IF). We determined, for the COL/ADP and P2Y cartridges, the median total volume (TVmedian), and RIs for CT, IF, TV, PHC1, and PHC2, and investigated the sensitivity and specificity of those parameters at the determined interpretation thresholds in determination of the clopidogrel effect. Healthy client-owned cats were recruited prospectively to determine RIs for CT, IF, TV, PHC1, and PHC2. Healthy blood-donor cats and cats on clopidogrel therapy were included retrospectively to determine test performance. In 20 healthy cats, RIs for COL/ADP were CT (19.5-87.2 s), IF (199-278 µL/min), TV (199-332 µL), PHC1 (94-106%), and PHC2 (52-148%); and for P2Y, CT (4.2-94.3 s), IF (112-208 µL/min), TV (151-294 µL), PHC1 (35-178%), and PHC2 (90-109%). CVs were calculated for all of these values. Specificity for detection of the clopidogrel effect was calculated from a group of healthy blood donors, and sensitivity for detection of the clopidogrel effect from a group of cats with known clopidogrel effect. Sensitivity and specificity were, for COL/ADP: CT (83.3%, 66.6%), IF (41.4%, 83.3%), TV (83.3%, 100%), PHC1 (100%, 100%) and PHC2 (100%, 83.3%); and for P2Y: CT (100%, 94.4%), IF (30%, 44.4%), TV (100%, 94.4%), PHC1 (100%, 100%), and PHC2 (100%, 97.7%). These PFA-200 values may be beneficial in the determination of platelet function in cats.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты