Hematology, transfusion and cell therapy · 2022
Correlation of serological and molecular markers in the screening for hepatitis B virus in blood bank in northern Brazil.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Cruz Lucas José do Nascimento, Barile Katarine Antonia Dos Santos, Amaral Carlos Eduardo de Melo
Аннотация
INTRODUCTION: In Brazil, the blood donor screening for hepatitis B virus (HBV) includes laboratory testing for serological (HBsAg and Anti-HBc) and molecular (HBV DNA) markers. This study aims to correlate serology reactive results with HBV DNA detection among blood donors with at least one HBV infection marker detected in a blood bank in northern Brazil.
METHOD: A retrospective search for HBV reactive blood donor data from January 2017 to December 2019 was performed. Serological screening was performed by chemiluminescent microparticle immunoassays Architect HBsAg and Architect Anti-HBc, whereas molecular screening was performed by the HBV nucleic acid test (HBV NAT).
MAIN RESULTS: A total of 556 HBsAg reactive results were detected, between positive (47.66%) and inconclusive (52.34%). A total of 3,658 Anti-HBc reactive results were detected, between positive (83.71%) and inconclusive (16.29%). None of the inconclusive results were associated with HBV DNA detection. The HBV DNA detection rates were 47.55% among HBsAg positive samples and 4.08% among Anti-HBc positive samples. The signal-to-cutoff (S/CO) ratio median of HBV NAT positive samples was superior in comparison to HBV NAT negative samples (p < 0.0001). The thresholds found to optimize sensitivity and specificity were 404.15 for Architect HBsAg and 7.77 for Architect Anti-HBc. Three blood donors were in the window period and 1 occult HBV infection case was detected.
CONCLUSION: High S/CO ratios were more predictive of HBV DNA detection. However, a number of HBV NAT positive samples gave low values, while some HBV NAT negative samples showed high values, reaffirming the significance of molecular testing to enhance transfusion safety.
METHOD: A retrospective search for HBV reactive blood donor data from January 2017 to December 2019 was performed. Serological screening was performed by chemiluminescent microparticle immunoassays Architect HBsAg and Architect Anti-HBc, whereas molecular screening was performed by the HBV nucleic acid test (HBV NAT).
MAIN RESULTS: A total of 556 HBsAg reactive results were detected, between positive (47.66%) and inconclusive (52.34%). A total of 3,658 Anti-HBc reactive results were detected, between positive (83.71%) and inconclusive (16.29%). None of the inconclusive results were associated with HBV DNA detection. The HBV DNA detection rates were 47.55% among HBsAg positive samples and 4.08% among Anti-HBc positive samples. The signal-to-cutoff (S/CO) ratio median of HBV NAT positive samples was superior in comparison to HBV NAT negative samples (p < 0.0001). The thresholds found to optimize sensitivity and specificity were 404.15 for Architect HBsAg and 7.77 for Architect Anti-HBc. Three blood donors were in the window period and 1 occult HBV infection case was detected.
CONCLUSION: High S/CO ratios were more predictive of HBV DNA detection. However, a number of HBV NAT positive samples gave low values, while some HBV NAT negative samples showed high values, reaffirming the significance of molecular testing to enhance transfusion safety.