MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.14919

Медицинская библиотека · Transfusion · 2018

Human immunodeficiency virus 1 dual-target nucleic acid technology improves blood safety: 5 years of experience of the German Red Cross blood donor service Baden-Württemberg-Hessen.

Hourfar Kai, Eberle Josef, Müller Markus, Micha Nübling C, Chudy Michael, Kress Julia, Gürtler Lutz, Mayr-Wohlfart Uschi, Schrezenmeier Hubert, Hellmann Inke, Luhm Jürgen, Kraas Sabine, Ringwald Jürgen, Gubbe Knut, Frank Kerstin, Karl Andreas, Tonn Torsten, Jaeger Maike, Sireis Walid, Seifried Erhard, Schmidt Michael

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

RNA viruses are associated with a high frequency of mutations because of the missing proofreading function of polymerases, such as reverse transcriptase. Between 2007 and 2010, six blood donations with false-negative nucleic acid technology (NAT) results were reported in Germany. Therefore, NAT screening in two viral genome regions was introduced by our blood donation service in 2010 on a voluntary basis and became mandatory in Germany since the beginning of 2015.

STUDY DESIGN AND

METHODS

Blood donor screening was done using, in parallel, the German Red Cross (GRC) HIV-1 CE long terminate repeats (LTR) PCR kit and the GRC HIV-1 gag CE PCR kit. In total, 7 million blood donations were screened during the study period from 2010 to 2014 with the GRC dual-target human immunodeficiency virus 1 (HIV-1) NAT system. Additionally, three suspicious specimens were analyzed by four monotargeted NAT assays and by five dual-target NAT assays.

RESULTS

Three of 7 million donations tested negative using the 5'LTR-polymerase chain reaction, but they were positive if amplification was performed in the gag region. HIV antibodies were detected in all three donations. Nucleic acid sequence analysis identified a deletion of 22 bases within the 5'LTR probe binding region. Three different ltr-based monotargeted assays missed two donations, except for a low-reactive result obtained by one of the assays. In total, the detection rates for HIV-1-positive donations were 37.5% (3/8) for monotargeted assays and 100% (10/10) for dual-target assays.

CONCLUSION

The current data demonstrate that dual-target NAT systems reduce the risk of false-negative HIV-1 NAT screening results.

Для цитирования: Hourfar Kai, Eberle Josef, Müller Markus, Micha Nübling C, Chudy Michael, Kress Julia, Gürtler Lutz, Mayr-Wohlfart Uschi, Schrezenmeier Hubert, Hellmann Inke, Luhm Jürgen, Kraas Sabine, Ringwald Jürgen, Gubbe Knut, Frank Kerstin, Karl Andreas, Tonn Torsten, Jaeger Maike, Sireis Walid, Seifried Erhard, Schmidt Michael. Human immunodeficiency virus 1 dual-target nucleic acid technology improves blood safety: 5 years of experience of the German Red Cross blood donor service Baden-Württemberg-Hessen.. Transfusion. 2018. DOI: 10.1111/trf.14919.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.