m+Medelevator.RU
← Поиск публикаций
Vox sanguinis · 2017

A uniform method for the simultaneous blood group phenotyping of Fya , Fyb , Jka , Jkb , S, s̅, P1, k applying lateral-flow technique.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Caesar A, Meyer S, Trost N, Neuenschwander K, Geisen C, Frey B M, Gassner C, Schwind P

Аннотация

BACKGROUND AND OBJECTIVES: A lateral flow assay for simultaneous blood group typing of ABO, RhD, C, E, c, e, Cw and K with stable end-point and without centrifugation is in routine use since several years (MDmulticard® ). The typing of extended phenotype parameters belonging to the Duffy, Kidd, MNSs blood group systems and others, however, has not yet been demonstrated for this technique. Reliable detection of Fyx , a weak Fyb phenotype with a pronounced quantitative reduction of the number of Fyb antigens on the erythrocyte surface, remains a weakness of current serological blood grouping techniques.

MATERIAL AND METHODS: The performance characteristics of the following reagents were evaluated in donor and patient samples in lateral flow technology (MDmulticard® ): Anti-Fya , -Fyb , -Jka , -Jkb , -S, -s̅, -P1 and -k. The sensitivity to detect Fyx was in addition evaluated with Fyx positive samples, which had been preselected by MALDI-TOF MS-based genotyping.

RESULTS: All results obtained with the MDmulticard® were in full accordance with those of the CE-certified reference products for all the eight reagent formulations used: Anti-Fya , -Fyb , -Jka , -Jkb , -S, -s̅, -P1 and -k. Also, all Fyx phenotypes of the selected population of 93 positive samples, originally identified by MALDI-TOF MS-based genotyping, were reliably detected by the lateral flow assay.

CONCLUSION: Extended phenotype blood group parameters, including the serologically challenging Fyx phenotype, can be determined simultaneously, rapidly and accurately using the lateral flow (MDmulticard® ) technology, even in cases when IgG class antibodies are the only source of diagnostic antibodies.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты