MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00365548.2014.926564

Медицинская библиотека · Scandinavian journal of infectious diseases · 2014

Screening tests for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus in blood donors: evaluation of two chemiluminescent immunoassay systems.

Sommese Linda, Sabia Chiara, Paolillo Rossella, Parente Delia, Capuano Maria, Iannone Carmela, Cavalca Francesco, Schiano Concetta, Vasco Maria, De Pascale Maria Rosaria, Casamassimi Amelia, Napoli Claudio

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

Automated chemiluminescent immunoassays (CLIAs) are useful for the detection of hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus 1/2 antigen/antibodies (HIV 1/2 Ag/Ab) in blood donor screening. Eight hundred and forty serum samples were tested for hepatitis B surface antigen (HBsAg), HCV antibodies (anti-HCV), and HIV1/2 Ag/Ab in parallel using 2 different CLIAs (Abbott Architect i2000SR and Roche Cobas e411). The concordance between the 2 systems was high (Cohen's kappa 0.97 for HBsAg, 0.77 for anti-HCV, 0.92 for HIV1/2 Ag/Ab) and the specificity and the positive predictive value were comparable. Among the 12 discrepant results, 11 were false-positive and 1 (reactive by Architect) was true-positive for anti-HCV. Positivity for HBV DNA, HCV RNA, and HIV RNA was recorded in 90.9%, 38.9%, and 100% of true-positive samples, respectively. This study represents the first stringent comparison between Architect i2000SR and Cobas e411 in blood donors. We observed a good correlation and high agreement among HBV, HCV, and HIV with the 2 automated systems.

Для цитирования: Sommese Linda, Sabia Chiara, Paolillo Rossella, Parente Delia, Capuano Maria, Iannone Carmela, Cavalca Francesco, Schiano Concetta, Vasco Maria, De Pascale Maria Rosaria, Casamassimi Amelia, Napoli Claudio. Screening tests for hepatitis B virus, hepatitis C virus, and human immunodeficiency virus in blood donors: evaluation of two chemiluminescent immunoassay systems.. Scandinavian journal of infectious diseases. 2014. DOI: 10.3109/00365548.2014.926564.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.