MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/vox.12016

Медицинская библиотека · Vox sanguinis · 2013

Determination of human neutrophil antigen-1, -3, -4 and -5 allele frequencies in English Caucasoid blood donors using a multiplex fluorescent DNA-based assay.

Cardoso S P, Chong W, Lucas G, Green A, Navarrete C

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

A number of DNA-based methods to genotype the alleles coding for HNA have been described, but all require the separate amplification and analysis of each allele. The aim was to develop a DNA-based method for simultaneous detection of HNA-1, HNA-3, HNA-4 and HNA-5 alleles.

MATERIALS AND

METHODS

An allele-specific primer extension method was used in combination with magnetic beads from Luminex technology. PCR-sequence-specific primers (SSP) was used to resolve the presence of the HNA-1b allele in samples assigned by the Luminex bead assay as HNA-1a/-1b/-1c or HNA-1b/-1c. HNA allele frequencies were determined in a panel of 140 randomly selected English Caucasoid blood donors.

RESULTS

HNA allelic types were compared with historical results, and 100% concordance was found. Only eight of the 97 samples used in the validation required additional testing by PCR-SSP. Allele frequencies were determined in the blood donor population as follows: 0·318 for HNA-1a, 0·668 for HNA-1b, 0·014 for HNA-1c, 0·768 for HNA-3a, 0·232 for HNA-3b, 0·882 for HNA-4a, 0·118 for HNA-4b, 0·736 for HNA-5a and 0·264 for HNA-5b.

CONCLUSION

A multiplex Luminex bead assay for the simultaneous detection of HNA-1, HNA-3, HNA-4 and HNA-5 alleles is described that enables rapid typing of donors to support HNA alloimmunized patients who require HNA-compatible blood products.

Для цитирования: Cardoso S P, Chong W, Lucas G, Green A, Navarrete C. Determination of human neutrophil antigen-1, -3, -4 and -5 allele frequencies in English Caucasoid blood donors using a multiplex fluorescent DNA-based assay.. Vox sanguinis. 2013. DOI: 10.1111/vox.12016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.