MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2012.03759.x

Медицинская библиотека · Transfusion · 2012

Events at blood collection area due to nonconforming blood bags and plateletpheresis kits: need for timely corrective and preventive actions.

Verma Anupam, Sachan Deepti, Elhence Priti, Pandey Hem, Dubey Anju

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Good blood banking practice requires that every effort should be made to detect any deviation or defect in blood bank products and to identify any potential risk to blood donor or recipient(s). We report the findings of an exercise that provide an insight into why feedback from the user side is crucial.

STUDY DESIGN AND

METHODS

Various events involving blood bags and plateletpheresis kits and the corresponding appropriate actions instituted for remedial measures were recorded. These scattered events were recorded for 6 months following the use of a new batch of improved blood bags with add-on features. Several events related to plateletpheresis kits from three different manufacturers were also recorded for 1 year.

RESULTS

The affected blood bags were utilized with no untoward incident. The complaint was closed following satisfactory response from the blood bag manufacturing company that acted in a timely manner in addressing the root causes of the problems. However, corrective and preventive actions (CAPA) could not be implemented for plateletpheresis kits. The rate of undesirable events was higher with plateletpheresis kits as compared with whole blood bags (1.75% vs. 0.06%).

CONCLUSION

As defects or deviations that trigger the need for CAPA can stem from numerous sources, it is important to clearly identify and document the problems and level of risk so that appropriate investigations can be instituted and remedial actions can be taken in a timely manner. This study demonstrates the usefulness of a quality initiative to collate and analyze blood product faults in conjunction with blood product manufacturers.

Для цитирования: Verma Anupam, Sachan Deepti, Elhence Priti, Pandey Hem, Dubey Anju. Events at blood collection area due to nonconforming blood bags and plateletpheresis kits: need for timely corrective and preventive actions.. Transfusion. 2012. DOI: 10.1111/j.1537-2995.2012.03759.x.