MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2006.04.017

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2006

Multicenter evaluation of the Bayer ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay.

Schappert Joseph, Wians Frank H, Schiff Eugene, Smalley David, Gambardella Ronald, Lee William M, Wu Jiaxi, Keiser Philip, Peterson Dolores, De Medina Maria, Baker Lawrence, Preisel-Simmons Barbara

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

It is important that serological assays detect antibodies to human immunodeficiency virus (HIV) in all infected individuals, including those infected with less prevalent, more diverse subtypes.

METHODS

Performance of the ADVIA Centaur HIV 1/O/2 Enhanced (EHIV) Assay was tested on 1344 samples from HIV-positive subjects, 6061 samples from groups at low-risk for HIV infection, and 1042 samples from groups at high-risk for HIV-1 and HIV-2 infection. Results were compared with those of an FDA-approved predicate assay.

RESULTS

The ADVIA Centaur EHIV Assay showed good precision with a diagnostic specificity of 99.9% and diagnostic sensitivity of 100%. HIV seroconversion was detected earlier in 6 panels, at the same time in 13 panels and later in only 1 of the panels when compared to the predicate assay, thereby narrowing the window period between infection and antibody detection. Of clinical significance, a blood donor sample that was indeterminate by HIV-1 Western blot and non-reactive by the predicate assay was repeatedly reactive in the ADVIA Centaur Assay and confirmed as positive by HIV-2 immunoblot.

CONCLUSIONS

The ADVIA Centaur EHIV Assay is useful as an aid in the diagnosis of individuals infected with HIV-1 and/or HIV-2.

Для цитирования: Schappert Joseph, Wians Frank H, Schiff Eugene, Smalley David, Gambardella Ronald, Lee William M, Wu Jiaxi, Keiser Philip, Peterson Dolores, De Medina Maria, Baker Lawrence, Preisel-Simmons Barbara. Multicenter evaluation of the Bayer ADVIA Centaur HIV 1/O/2 enhanced (EHIV) assay.. Clinica chimica acta; international journal of clinical chemistry. 2006. DOI: 10.1016/j.cca.2006.04.017.