MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Southeast Asian journal of tropical medicine and public health · 2004

The use of flow cytometry as a diagnostic test for malaria parasites.

Wongchotigul Varee, Suwanna Nirut, Krudsood Srivicha, Chindanond Duangrudee, Kano Shigeyuki, Hanaoka Nobuaki, Akai Yasumasa, Maekawa Yasunori, Nakayama Satoshi, Kojima Somei, Looareesuwan Sornchai

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A total of 453 clinical blood samples were determined for malaria parasites by flow cytometric assay (FCM) and reagents from Sysmex Corporation, Japan. In this study, the FCM greatly simplified and accelerated parasite detection, with sensitivity of 91.26%, specificity 86.28% and accuracy 87.42%. Overall, the parasite counts by flow cytometric measurement correlated well with the parasitemia measured by microscopic assay (regression coefficient = 0.9409). The detection limit was 0.05-0.1% parasitemia. No evidence of malaria parasites in either blood donor volunteers or other disease patients groups was determined by FCM. However, 48 samples who had been treated with antimalarial drugs and whose parasite microscopic counts were negative, showed false-positive results. When the data of these 48 samples were analyzed, they were found to have high levels of reticulocytes, ranging from 2.0-18.9%. This finding suggested that a high reticulocyte concentration in the blood may interfere with the performance of the FCM. Further improvement, by eliminating this interference, will make the FCM one of the most promising tests for malaria diagnosis.

Для цитирования: Wongchotigul Varee, Suwanna Nirut, Krudsood Srivicha, Chindanond Duangrudee, Kano Shigeyuki, Hanaoka Nobuaki, Akai Yasumasa, Maekawa Yasunori, Nakayama Satoshi, Kojima Somei, Looareesuwan Sornchai. The use of flow cytometry as a diagnostic test for malaria parasites.. The Southeast Asian journal of tropical medicine and public health. 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.