Vox sanguinis · 1998
Detection of HIV-1 RNA in two consecutive blood donations screened negative for HIV antibodies.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Burin des Roziers N, Coste J, Courouce A, Bibollet-Ruche F, Guillard A, Nasr O
Аннотация
BACKGROUND AND OBJECTIVES: An unusual serological pattern of HIV-1 seroconversion in a blood donor is described. The seroconversion panel was used to investigate the sensitivity of existing screening assays.
MATERIALS AND METHODS: A volunteer blood donor who had given blood 79 times was diagnosed anti-HIV-1-antibody-positive. The heteroduplex mobility assay identified a subtype B HIV-1 strain. The frozen plasmas from the last four blood donations had been kept at -30 degrees C. They were thawed and aliquoted for subsequent testing.
RESULTS: The last two blood donations contained HIV-1 RNA, 2,800 copies/ml (October 26) and 170 copies/ml (November 23). Weak anti-p24 antibodies were detected by Western blot in the October 26 sample, and a clear p24 reactivity along with a faint gp160 reactivity was observed on November 23. HIV p24 antigen was undetectable in both samples. Out of 13 screening assays, only 6 gave positive results on the November sample and 7 negative results which were obtained by 1 competitive enzyme immunoassay (EIA) and 6 of the 9 sandwich EIAs.
CONCLUSION: Most sandwich EIAs gave prolonged false-negative results in the present case. p24 antigen testing was negative and would not have reduced the risk of HIV transmission.
MATERIALS AND METHODS: A volunteer blood donor who had given blood 79 times was diagnosed anti-HIV-1-antibody-positive. The heteroduplex mobility assay identified a subtype B HIV-1 strain. The frozen plasmas from the last four blood donations had been kept at -30 degrees C. They were thawed and aliquoted for subsequent testing.
RESULTS: The last two blood donations contained HIV-1 RNA, 2,800 copies/ml (October 26) and 170 copies/ml (November 23). Weak anti-p24 antibodies were detected by Western blot in the October 26 sample, and a clear p24 reactivity along with a faint gp160 reactivity was observed on November 23. HIV p24 antigen was undetectable in both samples. Out of 13 screening assays, only 6 gave positive results on the November sample and 7 negative results which were obtained by 1 competitive enzyme immunoassay (EIA) and 6 of the 9 sandwich EIAs.
CONCLUSION: Most sandwich EIAs gave prolonged false-negative results in the present case. p24 antigen testing was negative and would not have reduced the risk of HIV transmission.