AIM: Evaluation of a qualitative HTLV-I/II DNA polymerase chain reaction (PCR) test for the detection of HTLV-I/II DNA (Roche Diagnostic Systems, Branchburg, N.J., USA) in various panels.

METHODS

The panels consisted of fresh EDTA blood samples from blood donors who were anti-HTLV-I/II ELISA repeatably reactive: 53 were Western blot (WB) positive, 228 were WB indeterminate and 15 were WB negative. Elevent ELISA-negative blood donors were used as negative controls. Furthermore, specimens from 1 HTLV-II-infected intravenous drug user and from 1 HTLV-II-infected blood donor were included in the panel. Peripheral blood lymphocytes were prepared by red blood cell lysis with the Roche washing solution and stored at < -23 degrees C until processing. Amplification products were analyzed with the HTLV-I/II detection kit.

RESULTS

All 53 anti-HTLV-I/II ELISA- and WB-positive samples and both HTLV-II-positive samples tested positively by PCR. All 228 anti-HTLV-I/II ELISA-positive and WB-indeterminate, all 15 ELISA-positive and WB-negative and all II ELISA-negative control samples tested negative by PCR.

CONCLUSION

The Roche Amplicor HTLV-I/II test is a simple test, suitable for the confirmation of HTLV-I and-II infection in individuals with indeterminate or positive WB patterns.

Для цитирования: Vrielink H, Zaaijer H L, Cuypers H T, van der Poel C L, Woerdeman M, Lelie P N, Winkel C, Reesink H W. Evaluation of a new HTLV-I/II polymerase chain reaction.. Vox sanguinis. 1997. DOI: 10.1046/j.1423-0410.1997.7230144.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.