[Hemoglobin in blood donor selection].

Chueca P M, Galar G M, Ardanaz M F, Zabalegui A, Muruzábal L, Muñoz A

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate and establish a relationship between serum ferritin value and haemoglobin level, serum iron or transferrin in volunteer blood donors.

MATERIAL AND

METHODS

We have studied a group of 479 blood donors from Navarra's Health Area V, whose blood cell examination, iron, ferritin and transferrin values were determined. We classified these donors in 4 groups according to their ferritin concentration (ng/mL): f1 (0-12), f2 (13-20), f3 (21-400) and f4 (more than 400). The results were analyzed by the statistical program SPSS/PC+. The sensitivity, specificity, accuracy and predictive value of the positive test, for the determination of haemoglobin level as an indicator of iron deposits were calculated.

RESULTS

The comparative statistical study of all these groups indicated that there were significant differences in the ferritin and the haemoglobin values (p < 0.001 and p < 0.05, respectively), except between f1 and f2, which only presented and intergroup difference in the ferritin values. In blood donors, the estimation of iron deposits from the hemoglobin level showed a diagnostic sensitivity greater than 90%.

CONCLUSIONS

Haemoglobin values would allow the selection of those donors that could have an iron deficiency, or a borderline concentration; nevertheless, it would not allow the distinction between these two groups. This last observation is not important because donors that show a ferritin value lower than 20 ng/mL should not give blood. When the ferritin is greater than 20 ng/mL in men, the iron deposits will be adequate in 97% of them. This percentage is about 90 in women whose haemoglobin level is greater than 12.5 g/dL. Therefore, we consider that haemoglobin values present a good cost/benefit ratio for donor selection.

Для цитирования: Chueca P M, Galar G M, Ardanaz M F, Zabalegui A, Muruzábal L, Muñoz A. [Hemoglobin in blood donor selection].. Sangre. 1995.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.