Limitations and Precautions in the Use of the Farnsworth-Munsell Dichotomous D-15 Test.

Dain Stephen J, Atchison David A, Hovis Jeffery K

СтатьяПеревод в очереди

Аннотация

SIGNIFICANCE: Clinicians who administer the Farnsworth-Munsell D-15 test need to pay attention to the quality and quantity of lighting and the time that they allow for completion of the test, and all repeat attempts need to be included in reports on compliance with color vision standards.

PURPOSE: The validity of the Farnsworth-Munsell D-15 has been questioned because practice may allow significantly color vision-deficient subjects to pass. In this article, we review the influence of practice and other factors that may affect the performance. These relate to both the design and the administration of the test.

METHODS

We review the literature and present some calculations on limitations in the colorimetric design of the test, quantity and quality of lighting, time taken, and repeat attempts.

RESULTS

In addition to the review of the literature, color differences and luminance differences under selected sources are calculated, and the increases in luminance clues under some sources and for protanopes are illustrated.

CONCLUSIONS

All these factors affect the outcome of the test and need specification and implementation if the test is to be applied consistently and equitably. We recommend the following: practitioners should never rely on a single color vision test regardless of the color vision standard; lighting should be Tcp '' 6500 K and Ra > 90; illuminance levels should be between 200 and 300 lux if detection of color vision deficiency is a priority or between 300 and 1000 lux if the need is to test at the level where illuminance has minimal influence on performance; illuminance should be reported; time limits should be set between 1 and 2 minutes; repeat testing (beyond the specified test and one retest) should be carried out only with authorization; and initial and repeated results should be reported. A set of test instructions to assist in the consistent application of the test is provided in the Appendix.

Для цитирования: Dain Stephen J, Atchison David A, Hovis Jeffery K. Limitations and Precautions in the Use of the Farnsworth-Munsell Dichotomous D-15 Test.. Optometry and vision science : official publication of the American Academy of Optometry. 2019. DOI: 10.1097/opx.0000000000001420.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.