m+Medelevator.RU
← Поиск публикаций
Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2018

Assessing Viral Transfer During Doffing of Ebola-Level Personal Protective Equipment in a Biocontainment Unit.

СтатьяПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Casanova Lisa M, Erukunuakpor Kimberly, Kraft Colleen S, Mumma Joel M, Durso Francis T, Ferguson Ashley N, Gipson Christina L, Walsh Victoria L, Zimring Craig, DuBose Jennifer, Jacob Jesse T, Centers for Disease Control and Prevention Epicenters Program, Division of Healthcare Quality Promotion

Аннотация

BACKGROUND: Personal protective equipment (PPE) protects healthcare workers (HCWs) caring for patients with Ebola virus disease (EVD), and PPE doffing is a critical point for preventing viral self-contamination. We assessed contamination of skin, gloves, and scrubs after doffing Ebola-level PPE contaminated with surrogate viruses: bacteriophages MS2 and Φ6.

METHODS: In a medical biocontainment unit, HCWs (n = 10) experienced in EVD care donned and doffed PPE following unit protocols that incorporate trained observer guidance and alcohol-based hand rub (ABHR). A mixture of Φ6 (enveloped), MS2 (nonenveloped), and fluorescent marker was applied to 4 PPE sites, approximating body fluid viral load (Φ6, 105; MS2, 106). They performed a patient care task, then doffed. Inner gloves, face, hands, and scrubs were sampled for virus, as were environmental sites with visible fluorescent marker.

RESULTS: Among 10 HCWs there was no Φ6 transfer to inner gloves, hands, or face; 1 participant had Φ6 on scrubs at low levels (1.4 × 102). MS2 transfer (range, 101-106) was observed to scrubs (n = 2), hands (n = 1), and inner gloves (n = 7), where it was highest. Most (n = 8) had only 1 positive site. Environmental samples with visible fluorescent marker (n = 21) were negative.

CONCLUSIONS: Among experienced HCWs, structured, observed doffing using ABHR protected against hand contamination with enveloped virus. Nonenveloped virus was infrequent on hands and scrubs but common on inner gloves, suggesting that inner gloves, but not necessarily ABHR, protect against hand contamination. Optimizing doffing protocols to protect against all types of viruses may require reinforcing careful handling of scrubs and good glove/hand hygiene with effective agents.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты