MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1681/asn.0000001183

Медицинская библиотека · Journal of the American Society of Nephrology : JASN · 2026

Donor Urinary Biomarkers and the Prediction of Deceased Donor Allograft Function.

Thiessen Philbrook Heather, Kerr Kathleen F, Mohan Sumit, DSouza Serena, Hu David G, Obeid Wassim, Mansour Sherry G, Hall Isaac E, Doshi Mona, Reese Peter P, Parikh Chirag R

СтатьяПеревод в очереди

Аннотация

KEY POINTS: Combining donor urinary biomarkers with Kidney Donor Profile Index improved the ability to predict paired recipient outcomes. Donor urinary biomarkers provided additional information on donor kidney quality, thus informing the kidney transplant allocation process.

BACKGROUND

Kidney transplant allocation currently relies on the Kidney Donor Profile Index (KDPI), a measure that has limitations. This study evaluated the potential of using KDPI and deceased donor urinary biomarkers to improve the assessment of organ quality and the prediction of allograft outcomes compared with KDPI alone.

METHODS

Pairs of kidney recipients from the same donor transplanted between 2010 and 2013 were followed for 3 years post-transplant from kidneys procured at five organ procurement organizations. By 3 years post-transplant, concordant good outcomes were defined as both recipients having an eGFR ≥45 ml/min per 1.73 m 2 , while concordant poor outcomes were defined as both recipients experiencing graft failure (return to dialysis or waitlisted) or having an eGFR <20 ml/min per 1.73 m 2 . Urinary biomarkers (uromodulin, osteopontin, and chitinase-3-like protein 1) were measured by immunoassay using a MesoScale Device in all donors and by lateral flow devices in a subset. Discriminatory ability was quantified with the area under the receiver operator characteristics curve (AUC).

RESULTS

We identified 474 donors with both kidneys transplanted and either concordant good outcomes (438; 92%) or concordant poor outcomes (36; 8%). For distinguishing concordant good from concordant poor outcomes, the AUC for KDPI alone was 0.80 (SE 0.04); the AUC for KDPI combined with uromodulin, osteopontin, and chitinase-3-like protein 1 measured by immunoassay was 0.86 (SE 0.03). In a subset of 105 donors with lateral flow device measurements, the AUC for KDPI plus three biomarkers was 0.85 (SE 0.04), compared with 0.81 (SE 0.05) for KDPI alone.

CONCLUSIONS

Combining donor urinary biomarkers with KDPI improved prediction of concordant allograft outcomes, regardless of assay platform. The improvement over KDPI alone was observed both with immunoassay and with point-of-care lateral flow device measurements.

Для цитирования: Thiessen Philbrook Heather, Kerr Kathleen F, Mohan Sumit, DSouza Serena, Hu David G, Obeid Wassim, Mansour Sherry G, Hall Isaac E, Doshi Mona, Reese Peter P, Parikh Chirag R. Donor Urinary Biomarkers and the Prediction of Deceased Donor Allograft Function.. Journal of the American Society of Nephrology : JASN. 2026. DOI: 10.1681/asn.0000001183.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.