DOI 10.1016/j.compbiomed.2024.109267
Nested Semi-Transparent Isosurface Simulated Volume-Rendering (NESTIS-VR) - An efficient on-device rendering approach for Augmented Reality headsets increasing surgeon confidence of kidney donor arterial anatomy.
Аннотация
BACKGROUND AND
OBJECTIVE
Volume-renderings of computed tomography or magnetic resonance angiograms (MRAs) are routinely used by surgeons in the preoperative assessment of vascular anatomy in kidney donors. Stereoscopic headsets (OST-HMD) like Microsoft HoloLens allow intuitive interaction with three-dimensional content for more intuitive comprehension, but do not allow real-time ray-casting volume-rendering of medical volume datasets on-device due to computational limitations.
METHODS
We introduce NEsted Semi-Transparent Isosurface Simulated Volume-Rendering (NESTIS-VR), as an on-device alternative to ray-casting volume-rendering and developed an application for HoloLens to render kidney donor MRAs with interactive control of fundamental rendering parameters. We compared NESTIS-VR with current standard pre-calculated 2D ray-cast volume-renderings in an observational study with 2 expert kidney transplant surgeons, measuring their confidence in pre-operatively assessing the kidney pedicle arterial anatomy in 20 potential donors. We also compared it against other 3D rendering techniques to understand which features contributed most to any improvements.
RESULTS
Real-time stereoscopic three-dimensional (3D) NESTIS-VR in Augmented Reality significantly improves surgeons' confidence compared with pre-calculated conventional two-dimensional (2D) ray-casting volume-rendered images (p = 0.0415/p = 0.00003). 2D non-stereoscopic NESTIS-VR was significantly superior to pre-calculated 2D ray-casting volume-rendered images for both surgeons (p = 0.044/p = 0.0003). Single isosurface 2D rendering was significantly superior than pre-calculated 2D volume-rendered images for one surgeon. There was no significant difference between binocular 3D display over 2D views with NESTIS-VR or between constrained and unconstrained vantage points for 2D viewing.
CONCLUSION
NESTIS-VR provides a new approach to rendering medical datasets in computationally limited OST-HMD headsets and significantly increases surgeons' confidence of kidney donor arterial anatomy. The principal confidence benefit arises from providing surgeons interactive control over rendering parameters compared to pre-calculated renderings at preset parameters whilst rendering on-device and keeping the OST-HMD untethered from a workstation.