Prediction of measured GFR after living kidney donation from pre-donation parameters.

van Londen Marco, van der Weijden Jessica, Niznik Robert S, Mullan Aidan F, Bakker Stephan J L, Berger Stefan P, Nolte Ilja M, Sanders Jan-Stephan F, Navis Gerjan, Rule Andrew D, de Borst Martin H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

One of the challenges in living kidney donor screening is to estimate remaining kidney function after donation. Here we developed a new model to predict post-donation measured glomerular filtration rate (mGFR) from pre-donation serum creatinine, age and sex.

METHODS

In the prospective development cohort (TransplantLines, n = 511), several prediction models were constructed and tested for accuracy, precision and predictive capacity for short- and long-term post-donation 125I-iothalamate mGFR. The model with optimal performance was further tested in specific high-risk subgroups (pre-donation eGFR <90 mL/min/1.73 m2, a declining 5-year post-donation mGFR slope or age >65 years) and validated in internal (n = 509) and external (Mayo Clinic, n = 1087) cohorts.

RESULTS

In the development cohort, pre-donation estimated GFR (eGFR) was 86 ± 14 mL/min/1.73 m2 and post-donation mGFR was 64 ± 11 mL/min/1.73 m2. Donors with a pre-donation eGFR ≥90 mL/min/1.73 m2 (present in 43%) had a mean post-donation mGFR of 69 ± 10 mL/min/1.73 m2 and 5% of these donors reached an mGFR <55 mL/min/1.73 m2. A model using pre-donation serum creatinine, age and sex performed optimally, predicting mGFR with good accuracy (mean bias 2.56 mL/min/1.73 m2, R2 = 0.29, root mean square error = 11.61) and precision [bias interquartile range (IQR) 14 mL/min/1.73 m2] in the external validation cohort. This model also performed well in donors with pre-donation eGFR <90 mL/min/1.73 m2 [bias 0.35 mL/min/1.73 m2 (IQR 10)], in donors with a negative post-donation mGFR slope [bias 4.75 mL/min/1.73 m2 (IQR 13)] and in donors >65 years of age [bias 0.003 mL/min/1.73 m2 (IQR 9)].

CONCLUSIONS

We developed a novel post-donation mGFR prediction model based on pre-donation serum creatinine, age and sex.

Для цитирования: van Londen Marco, van der Weijden Jessica, Niznik Robert S, Mullan Aidan F, Bakker Stephan J L, Berger Stefan P, Nolte Ilja M, Sanders Jan-Stephan F, Navis Gerjan, Rule Andrew D, de Borst Martin H. Prediction of measured GFR after living kidney donation from pre-donation parameters.. Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 2023. DOI: 10.1093/ndt/gfac202.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.