DOI 10.1159/000449207

Медицинская библиотека · Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie · 2016

HCV RNA Testing of Plasma Samples from Cornea Donors: Suitability of Plasma Samples Stored at 4 °C for up to 8 Days.

Berger Annemarie, Salla Sabine, Keppler Oliver T, Rabenau Holger F

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The HCV RNA testing of potential cornea donors frequently relies on blood samples stored pre mortem. The recommended storage time of maximum 72 h frequently excludes a significant fraction of donors.

METHODS

The influence of storage time of EDTA plasma samples at 4 °C on the viral load measured with the Roche HCV Quantitative Test vs. 2.0 was evaluated for 43 samples from HCV-positive individuals.

RESULTS

The mean reduction of the viral load after 4 °C storage for 6-8 days was 0.46 log10 IU/ml (range +0.17 to -1.66 log10 IU/ml). After 1-3 days a mean loss of 0.19 log10 IU/ml (range +0.30 to -1.41 log10 IU/ml) and after 3-5 days of 0.32 log10 IU/ml (range +0.36 to -1.81 log10 IU/ml) was observed. In 23.3% of samples, a viral load reduction ≥ 1 log10 IU/ml (1.0-1.81 log10 IU/ml) was found after prolonged storage (5-8 days). In none of the samples did the HCV load fall below the detection limit.

CONCLUSION

Plasma storage for up to 8 days can quantitatively reduce the HCV RNA load, yet has no influence on the reliability of a qualitative HCV RNA detection by this ultrasensitive test to determine the HCV status of serologically negative cornea donors.

Для цитирования: Berger Annemarie, Salla Sabine, Keppler Oliver T, Rabenau Holger F. HCV RNA Testing of Plasma Samples from Cornea Donors: Suitability of Plasma Samples Stored at 4 °C for up to 8 Days.. Transfusion medicine and hemotherapy : offizielles Organ der Deutschen Gesellschaft fur Transfusionsmedizin und Immunhamatologie. 2016. DOI: 10.1159/000449207.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.