m+Medelevator.RU
← Поиск публикаций
Journal of cataract and refractive surgery · 2014

Textural interface opacity after Descemet-stripping automated endothelial keratoplasty.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kim Keunsoo, Alder Brian, Vora Gargi K, Carlson Alan N, Afshari Natalie A, Kuo Anthony N, Kim Terry

Аннотация

PURPOSE: To describe cases of interface haze, also known as textural interface opacity, after Descemet-stripping automated endothelial keratoplasty (DSAEK).

SETTING: Department of Cornea, External Disease, and Refractive Surgery Service, Duke Eye Center, Durham, North Carolina, USA.

DESIGN: Retrospective case series.

METHODS: Patients' clinical and demographic characteristics, cornea donor information, surgical technique, histopathology, and anterior segment optical coherence tomography (OCT) were reviewed retrospectively and clinical outcomes reported.

RESULTS: The interface haze that developed after DSAEK comprised 2 types of textural interface opacity; that is, total (11 cases) and partial (3 cases). The time of onset of textural interface opacity ranged from 1 day to 7 weeks postoperatively. Although most patients with textural interface opacity showed improvement, with a corrected distance visual acuity better than 20/50, 3 had persistent decreased visual acuity and required repeat DSAEK. Seven eyes had concurrent phacoemulsification with intraocular lens implantation and DSAEK. The corneal graft was inserted with an Endoserter device in 11 eyes, an insertion forceps in 2 eyes, and a cystotome needle in 1 eye. Histopathology of the grafts of eyes that required repeat DSAEK showed no inflammation, no foreign-body deposit, and no fibrosis. Anterior segment OCT showed increased hyperreflectivity in the interface.

CONCLUSIONS: Although the etiology of textural interface opacity is unclear, it may be related to retained ophthalmic viscosurgical device (OVD) or an adhesive property of the OVD used during the surgery. Although most cases resolve with time, repeat DSAEK may be an effective treatment for refractory cases.

FINANCIAL DISCLOSURE: Dr. Kim is a consultant to Ocular Systems, Inc. No other author has a financial or proprietary interest in any material or method mentioned.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты