m+Medelevator.RU
← Поиск публикаций
European journal of radiology · 2017

Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography.

Сравнительное исследованиеОценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yamashita Rikiya, Isoda Hiroyoshi, Arizono Shigeki, Ono Ayako, Onishi Natsuko, Furuta Akihiro, Togashi Kaori

Аннотация

OBJECTIVE: To compare the diagnostic performance of non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE-MRV) and conventional computed tomography venography (CTV) in preoperative evaluation of venous tributaries for living donor liver transplantation.

MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this prospective study of 73 donor candidates. Of these, 23 underwent right-sided graft hepatectomy without middle hepatic vein. One or more tributaries, other than the right hepatic vein, were reconstructed for 20 of the 23 grafts. For these 20 grafts, the number and location of the tributaries requiring reconstruction were evaluated based on venography, and diagnostic performance was analyzed using surgical records as a reference standard. For each candidate, the number of small tributaries directly joining the inferior vena cava was counted in each venographic image; a paired-sample t-test was used to assess differences. The severity of respiratory artifacts in MPRAGE-MRV was qualitatively evaluated, and compared using Wilcoxon's rank-sum test.

RESULTS: All reconstructed venous tributaries were prospectively identified using both methods. MPRAGE-MRV tended to provide a greater number of small tributaries than conventional CTV (mean: 2; 95% CI: [1.66, 2.34], and 1.74; [1.44, 2.04], respectively), although the difference was not significant (P=0.10); MPRAGE-MRV was superior or equal to CTV in 52 subjects (71.2%), and inferior in 21 subjects (28.8%). Respiratory artifacts were significantly less severe in the former subjects (P<0.0001).

CONCLUSIONS: MPRAGE-MRV has the potential to replace conventional CTV in the preoperative evaluation of living liver donor candidates.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты