MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.24964

Медицинская библиотека · Magnetic resonance in medicine · 2013

Feasibility of semiautomated MR volumetry using gadoxetic acid-enhanced MRI at hepatobiliary phase for living liver donors.

Lee Jeongjin, Kim Kyoung Won, Kim So Yeon, Kim Bohyoung, Lee So Jung, Kim Hyoung Jung, Lee Jong Seok, Lee Moon Gyu, Song Gi-Won, Hwang Shin, Lee Sung-Gyu

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the feasibility of semiautomated MR volumetry using gadoxetic acid-enhanced MRI at the hepatobiliary phase compared with manual CT volumetry.

METHODS

Forty potential live liver donor candidates who underwent MR and CT on the same day, were included in our study. Semiautomated MR volumetry was performed using gadoxetic acid-enhanced MRI at the hepatobiliary phase. We performed the quadratic MR image division for correction of the bias field inhomogeneity. With manual CT volumetry as the reference standard, we calculated the average volume measurement error of the semiautomated MR volumetry. We also calculated the mean of the number and time of the manual editing, edited volume, and total processing time.

RESULTS

The average volume measurement errors of the semiautomated MR volumetry were 2.35% ± 1.22%. The average values of the numbers of editing, operation times of manual editing, edited volumes, and total processing time for the semiautomated MR volumetry were 1.9 ± 0.6, 8.1 ± 2.7 s, 12.4 ± 8.8 mL, and 11.7 ± 2.9 s, respectively.

CONCLUSION

Semiautomated liver MR volumetry using hepatobiliary phase gadoxetic acid-enhanced MRI with the quadratic MR image division is a reliable, easy, and fast tool to measure liver volume in potential living liver donors.

Для цитирования: Lee Jeongjin, Kim Kyoung Won, Kim So Yeon, Kim Bohyoung, Lee So Jung, Kim Hyoung Jung, Lee Jong Seok, Lee Moon Gyu, Song Gi-Won, Hwang Shin, Lee Sung-Gyu. Feasibility of semiautomated MR volumetry using gadoxetic acid-enhanced MRI at hepatobiliary phase for living liver donors.. Magnetic resonance in medicine. 2013. DOI: 10.1002/mrm.24964.