MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.transproceed.2018.05.024

Медицинская библиотека · Transplantation proceedings · 2018

Application of Nonlinear Optical Microscopic Imaging Technology for Quality Assessment of Donor Kidneys.

Huang H W, Liu D, Hu J M, Xu S Y, Zhuo S M, Liu Y G, Zhao M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Nonlinear optical microscopic (NLOM) imaging technique shows its high resolution imaging features in histocytology. The purpose of this study was to investigate NLOM imaging technique as a useful tool for a donor kidney quality assessment.

MATERIALS AND

METHODS

Eighty-three pretransplant kidney biopsies from adult donors were analyzed retrospectively. Each specimen was paraffin-embedded and sectioned into 2 consecutive 5-μm thick sections. One section was stained with Masson trichrome, and the other was left unstained for NLOM imaging using second harmonic generation combined with two-photon excited fluorescence (SHG/TPEF). The pretransplant kidney quality was assessed by an experienced pathologist using the Remuzzi scoring system, which characterizes renal tissue morphology into 4 aspects: tubular atrophy, interstitial fibrosis, glomerulosclerosis, and vascular injury. The K coefficient was used to measure the consistency of the Remuzzi scores between conventional Masson trichrome stained images and SHG/TPEF images.

RESULTS

NLOM imaging technology can capture high-resolution tissue images from unstained renal tissue, is easy to operate, and shortens time-consuming histological processing procedures. No significant differences (P > .05) were found between the Remuzzi scores of the SHG/TPEF images and the Masson trichrome stained images. The high κ coefficients (0.804-0.895) showed a good consistency between these 2 techniques.

CONCLUSION

The NLOM technique is suitable for renal tissue imaging and could potentially be used for routine pretransplant kidney evaluation in clinical settings.

Для цитирования: Huang H W, Liu D, Hu J M, Xu S Y, Zhuo S M, Liu Y G, Zhao M. Application of Nonlinear Optical Microscopic Imaging Technology for Quality Assessment of Donor Kidneys.. Transplantation proceedings. 2018. DOI: 10.1016/j.transproceed.2018.05.024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.