Cornea · 2015
Postoperative Graft Thickness Obtained With Single-Pass Microkeratome-Assisted Ultrathin Descemet Stripping Automated Endothelial Keratoplasty.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Nahum Yoav, Leon Pia, Busin Massimo
Аннотация
PURPOSE: To evaluate the results of microkeratome-assisted ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) using a nomogram developed for the single-pass technique.
METHODS: A retrospective study of eyes operated between September 2014 and March 2015 at Villa Serena-Villa Igea Private Hospitals (Forlì, Italy) by a single surgeon (M.B.). Study eyes underwent UT-DSAEK performed using a linear microkeratome-assisted lamellar dissection with disposable heads of different sizes (Moria ALTK system; Moria SA) chosen according to a pachymetry-based nomogram developed at our department. The main outcome measure was the graft thickness as assessed by means of anterior segment optical coherence tomography, measured between 1 and 3 months postoperatively.
RESULTS: Forty-two eyes were included in this study. Mean follow-up time was 5.0 ± 1.8 months (range 1.2-6.9 months). No perforation or other complication occurred during graft preparation. Mean postoperative central thickness of donor grafts was 63 ± 29 μm. Thickness ranged between 23 and 177 μm, and the second thickest graft measured 116 μm. By 3 months postoperatively, 41/42 (97%) of the grafts were of thickness ≤130 μm and 38/42 (90%) of the grafts were of central thickness ≤100 μm. The mean nasal-to-temporal absolute thickness difference at the graft's central 3-mm zone was 5 ± 7 μm at the last available measurement.
CONCLUSIONS: The nomogram developed at our institution allowed reliable single-pass microkeratome-assisted dissection of donor tissue, creating consistently thin and symmetric grafts without loss of tissue. The results obtained compare favorably with those reported in the past for double-pass microkeratome-assisted dissection of UT-DSAEK.
METHODS: A retrospective study of eyes operated between September 2014 and March 2015 at Villa Serena-Villa Igea Private Hospitals (Forlì, Italy) by a single surgeon (M.B.). Study eyes underwent UT-DSAEK performed using a linear microkeratome-assisted lamellar dissection with disposable heads of different sizes (Moria ALTK system; Moria SA) chosen according to a pachymetry-based nomogram developed at our department. The main outcome measure was the graft thickness as assessed by means of anterior segment optical coherence tomography, measured between 1 and 3 months postoperatively.
RESULTS: Forty-two eyes were included in this study. Mean follow-up time was 5.0 ± 1.8 months (range 1.2-6.9 months). No perforation or other complication occurred during graft preparation. Mean postoperative central thickness of donor grafts was 63 ± 29 μm. Thickness ranged between 23 and 177 μm, and the second thickest graft measured 116 μm. By 3 months postoperatively, 41/42 (97%) of the grafts were of thickness ≤130 μm and 38/42 (90%) of the grafts were of central thickness ≤100 μm. The mean nasal-to-temporal absolute thickness difference at the graft's central 3-mm zone was 5 ± 7 μm at the last available measurement.
CONCLUSIONS: The nomogram developed at our institution allowed reliable single-pass microkeratome-assisted dissection of donor tissue, creating consistently thin and symmetric grafts without loss of tissue. The results obtained compare favorably with those reported in the past for double-pass microkeratome-assisted dissection of UT-DSAEK.