MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000000603

Медицинская библиотека · Cornea · 2015

Postoperative Graft Thickness Obtained With Single-Pass Microkeratome-Assisted Ultrathin Descemet Stripping Automated Endothelial Keratoplasty.

Nahum Yoav, Leon Pia, Busin Massimo

СтатьяПеревод в очереди

Аннотация

PURPOSE: To evaluate the results of microkeratome-assisted ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) using a nomogram developed for the single-pass technique.

METHODS

A retrospective study of eyes operated between September 2014 and March 2015 at Villa Serena-Villa Igea Private Hospitals (Forlì, Italy) by a single surgeon (M.B.). Study eyes underwent UT-DSAEK performed using a linear microkeratome-assisted lamellar dissection with disposable heads of different sizes (Moria ALTK system; Moria SA) chosen according to a pachymetry-based nomogram developed at our department. The main outcome measure was the graft thickness as assessed by means of anterior segment optical coherence tomography, measured between 1 and 3 months postoperatively.

RESULTS

Forty-two eyes were included in this study. Mean follow-up time was 5.0 ± 1.8 months (range 1.2-6.9 months). No perforation or other complication occurred during graft preparation. Mean postoperative central thickness of donor grafts was 63 ± 29 μm. Thickness ranged between 23 and 177 μm, and the second thickest graft measured 116 μm. By 3 months postoperatively, 41/42 (97%) of the grafts were of thickness ≤130 μm and 38/42 (90%) of the grafts were of central thickness ≤100 μm. The mean nasal-to-temporal absolute thickness difference at the graft's central 3-mm zone was 5 ± 7 μm at the last available measurement.

CONCLUSIONS

The nomogram developed at our institution allowed reliable single-pass microkeratome-assisted dissection of donor tissue, creating consistently thin and symmetric grafts without loss of tissue. The results obtained compare favorably with those reported in the past for double-pass microkeratome-assisted dissection of UT-DSAEK.

Для цитирования: Nahum Yoav, Leon Pia, Busin Massimo. Postoperative Graft Thickness Obtained With Single-Pass Microkeratome-Assisted Ultrathin Descemet Stripping Automated Endothelial Keratoplasty.. Cornea. 2015. DOI: 10.1097/ico.0000000000000603.