MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00395-013-0346-0

Медицинская библиотека · Basic research in cardiology · 2013

A highly sensitive and accurate method to quantify absolute numbers of c-kit+ cardiac stem cells following transplantation in mice.

Hong Kyung U, Li Qian-Hong, Guo Yiru, Patton Nikita S, Moktar Afsoon, Bhatnagar Aruni, Bolli Roberto

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

Although transplantation of c-kit+ cardiac stem cells (CSCs) alleviates post-myocardial infarction left ventricular dysfunction, there are no reliable methods that enable measurement of the absolute number of CSCs that persist in the recipient heart. To overcome this limitation, we developed a highly sensitive and accurate method to quantify the absolute number of murine CSCs after transplantation. This method has two unique features: (1) real-time PCR-based detection of a novel male-specific, multiple-copy gene, Rbmy, which significantly increases the sensitivity of detection of male donor cells in a female recipient, and (2) an internal standard, which permits quantification of the absolute number of CSCs as well as the total number of cells in the recipient organ. Female C57BL/6 mice underwent coronary occlusion and reperfusion; 2 days later, 10(5) male mouse CSCs were injected intramyocardially. Tissues were analyzed by real-time PCR at serial time points. In the risk region, >75 % of CSCs present at 5 min were lost in the ensuing 24 h; only 7.6 ± 2.1 % of the CSCs present at 5 min could still be found at 7 days after transplantation and only 2.8 ± 0.5 % (i.e., 1,224 ± 230 cells/heart) at 35 days. Thus, even after direct intramyocardial injection, the total number of CSCs that remain in the murine heart is minimal (at 24 h, ~10 % of the cells injected; at 35 days, ~1 %). This new quantitative method of stem cell detection, which enables measurement of absolute cell number, should be useful to optimize cell-based therapies, not only for CSCs but also for other stem cells and other organs.

Для цитирования: Hong Kyung U, Li Qian-Hong, Guo Yiru, Patton Nikita S, Moktar Afsoon, Bhatnagar Aruni, Bolli Roberto. A highly sensitive and accurate method to quantify absolute numbers of c-kit+ cardiac stem cells following transplantation in mice.. Basic research in cardiology. 2013. DOI: 10.1007/s00395-013-0346-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.