MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.joms.2010.10.037

Медицинская библиотека · Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons · 2011

Sinus graft with safescraper: 5-year results.

Caubet Jorge, Petzold Christiane, Sáez-Torres Concepción, Morey Miguel, Iriarte José Ignacio, Sánchez Jacobo, Torres J Juan, Ramis Joana M, Monjo Marta

СтатьяПеревод в очереди

Аннотация

PURPOSE: In the procedure of sinus floor elevation, autogenous bone, allogenic grafts, and several other bone substitutes are used. However, autogenous bone is still considered the gold standard. Donor sites for autogenous bone are generally the iliac crest, oral cavity, calvarium bone, and tibia. In this work the experience with the use of a Safescraper device for harvesting of autogenous bone is reported and a decision-making algorithm for grafting in sinus floor elevation procedures is proposed.

MATERIALS AND

METHODS

Forty sinus augmentation procedures were performed in 34 patients. All sinuses were filled with a mixture of autogenous bone and bovine hydroxyapatite. A Safescraper device was used to harvest autologous bone from the maxillary area. Platelet-rich plasma was used to sustain bone placement. Sixty-five dental implants were placed at 4 months with a flapless procedure. A clinical and radiological 5-year retrospective case series of a cohort is reported.

RESULTS

In all cases new bone formation was confirmed radiologically and implant placement was performed successfully. Analysis of samples obtained by biopsy with histology and microcomputed tomography showed the presence of mature bone. Healing problems were observed in only 1 case.

CONCLUSIONS

Sinus augmentation with bone grafts obtained from oral cavity with a bone scraper device has the advantage of providing autogenous bone without the need for an extra surgical approach. This procedure yields satisfactory results in bone formation, implant survival, and patient satisfaction. When combined with a flapless approach for implant placement, a decrease in the morbidity of the entire process is achieved.

Для цитирования: Caubet Jorge, Petzold Christiane, Sáez-Torres Concepción, Morey Miguel, Iriarte José Ignacio, Sánchez Jacobo, Torres J Juan, Ramis Joana M, Monjo Marta. Sinus graft with safescraper: 5-year results.. Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons. 2011. DOI: 10.1016/j.joms.2010.10.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.