International journal of legal medicine · 2026
Development of a deep learning-based tool for coronary artery stenosis evaluation in forensic autopsies using whole slide imaging.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pigaiani Nicola, Sharifi Shakiba, Garavello Marianna, Setti Francesco, Ausania Francesco, Bortolotti Federica, Chighine Alberto, D'Aloja Ernesto, Rodegher Pamela, Ammendola Serena, Brunelli Matteo, Cristani Marco, Gobbo Stefano
Аннотация
BACKGROUND: Cardiovascular disease is a leading cause of mortality, with coronary artery disease accounting for over 60% of cases in adults. Accurate quantification of coronary stenosis in forensic autopsies is crucial for determining causality between pathological findings and death, but is hindered by subjective visual assessments and inter-observer variability. This study aimed to develop an AI-driven tool using whole-slide images for objective stenosis measurement in forensic investigations. MATERIALS AND METHODS: From 98 anonymized H&E-stained autopsy slides (234 coronary sections), 103 high-quality regions of interest were selected and split into training (n = 82), validation (n = 14), and test (n = 7) datasets. Annotations delineated lumen, internal elastic lamina, and external elastic lamina using QuPath. A SegFormer-B0 transformer model was trained with data augmentation, weighted cross-entropy loss, and AdamW optimization. Post-processing enforced anatomical structural hierarchy and generated hybrid confidence maps. RESULTS: On validation dataset, agreement with ground truth was excellent (MAE 3.22% points; RMSE 4.00; MAPE 6.07%; r = 0.986; ICC = 0.986), with slight underestimation. Bland–Altman bias was − 1.36 pp (95% LoA − 9.01 to 6.28 pp), indicating performance across severities. On the test set, accuracy improved (MAE 1.01 pp; RMSE 1.50; MAPE 2.11%; r = 0.998; ICC = 0.995) and outperformed three pathologists’ visual estimates (MAE 16.11, 8.18, 4.79 pp). Bland–Altman bias for the model was − 0.82 pp with tight limits of agreement (− 3.48 to 1.83 pp). Total inference time was 199.08 s for seven cases (28.44 s/image). CONCLUSIONS: WSI-based transformer pipeline enables rapid, auditable, and reproducible coronary stenosis measurement, reducing inter-observer variability and supporting standardized interpretation in forensic investigations.