The Journal of thoracic and cardiovascular surgery · 1999
Primary aortic valve replacement with allografts over twenty-five years: valve-related and procedure-related determinants of outcome.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lund O, Chandrasekaran V, Grocott-Mason R, Elwidaa H, Mazhar R, Khaghani A, Mitchell A, Ilsley C, Yacoub M H
Аннотация
OBJECTIVES: Allografts offer many advantages over prosthetic valves, but allograft durability varies considerably.
METHODS: From 1969 through 1993, 618 patients aged 15 to 84 years underwent their first aortic valve replacement with an aortic allograft. Concomitant surgery included aortic root tailoring (n = 58), replacement or tailoring of the ascending aorta (n = 56), and coronary artery bypass grafting (n = 87). Allograft implantation was done by means of a "freehand" subcoronary technique (n = 551) or total root replacement (n = 67). The allografts were antibiotic sterilized (n = 479), cryopreserved (n = 12), or viable (unprocessed, harvested from brain-dead multiorgan donors or heart transplant recipients, n = 127). Maximum follow-up was 27.1 years.
RESULTS: Thirty-day mortality was 5.0%, and crude survival was 67% and 35% at 10 and 20 years. Ten- and 20-year rates of freedom from complications were as follows: endocarditis, 93% and 89%; primary tissue failure, 62% and 18%; and redo aortic valve replacement, 81% and 35%. Multivariable Cox analyses identified several valve- and procedure-related determinants: rising allograft donor age and antibiotic-sterilized allograft for mortality; donor more than 10 years older than patient for endocarditis; rising donor age minus patient age, rising implantation time (from harvest to aortic valve replacement), and donor age more than 65 years for tissue failure; and rising donor age minus patient age, young patient age, rising implantation time, and subcoronary implantation preceded by aortic root tailoring for redo aortic valve replacement. Estimated 10- and 20-year rates of freedom from tissue failure for a 70-year-old patient with a viable valve from a 30-year-old donor and no other risk factors were 91% and 64%; the figures were 71% and 20% if the donor age was 65 years. The rates of freedom from tissue failure for a 30-year-old patient with a 30-year-old donor were 82% and 39%; the figures were 49% and 3% with a 65-year-old donor. Beneficial influences of a viable valve were largely covered by short harvest time (no delay for allografts from brain dead organ donors or heart transplant recipients) and short implantation time.
CONCLUSIONS: Primary allograft aortic valve replacement can give acceptable results for up to 25 years. The late results can be improved by the use of a viable allograft, by matching patient and donor age, and by more liberal use of free root replacement with re-implantation of the coronary arteries rather than tailoring the root to accommodate a subcoronary implantation.
METHODS: From 1969 through 1993, 618 patients aged 15 to 84 years underwent their first aortic valve replacement with an aortic allograft. Concomitant surgery included aortic root tailoring (n = 58), replacement or tailoring of the ascending aorta (n = 56), and coronary artery bypass grafting (n = 87). Allograft implantation was done by means of a "freehand" subcoronary technique (n = 551) or total root replacement (n = 67). The allografts were antibiotic sterilized (n = 479), cryopreserved (n = 12), or viable (unprocessed, harvested from brain-dead multiorgan donors or heart transplant recipients, n = 127). Maximum follow-up was 27.1 years.
RESULTS: Thirty-day mortality was 5.0%, and crude survival was 67% and 35% at 10 and 20 years. Ten- and 20-year rates of freedom from complications were as follows: endocarditis, 93% and 89%; primary tissue failure, 62% and 18%; and redo aortic valve replacement, 81% and 35%. Multivariable Cox analyses identified several valve- and procedure-related determinants: rising allograft donor age and antibiotic-sterilized allograft for mortality; donor more than 10 years older than patient for endocarditis; rising donor age minus patient age, rising implantation time (from harvest to aortic valve replacement), and donor age more than 65 years for tissue failure; and rising donor age minus patient age, young patient age, rising implantation time, and subcoronary implantation preceded by aortic root tailoring for redo aortic valve replacement. Estimated 10- and 20-year rates of freedom from tissue failure for a 70-year-old patient with a viable valve from a 30-year-old donor and no other risk factors were 91% and 64%; the figures were 71% and 20% if the donor age was 65 years. The rates of freedom from tissue failure for a 30-year-old patient with a 30-year-old donor were 82% and 39%; the figures were 49% and 3% with a 65-year-old donor. Beneficial influences of a viable valve were largely covered by short harvest time (no delay for allografts from brain dead organ donors or heart transplant recipients) and short implantation time.
CONCLUSIONS: Primary allograft aortic valve replacement can give acceptable results for up to 25 years. The late results can be improved by the use of a viable allograft, by matching patient and donor age, and by more liberal use of free root replacement with re-implantation of the coronary arteries rather than tailoring the root to accommodate a subcoronary implantation.
Предметные рубрики MeSH
AgedAortaAortic ValveAortic Valve InsufficiencyAortic Valve StenosisBlood Vessel Prosthesis ImplantationCardiopulmonary BypassEndocarditisFemaleHumansMaleMiddle AgedPostoperative ComplicationsProportional Hazards ModelsRetrospective StudiesSurvival AnalysisTransplantation, HomologousTreatment Outcome