MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0022-5223(99)70471-x

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 1999

Primary aortic valve replacement with allografts over twenty-five years: valve-related and procedure-related determinants of outcome.

Lund O, Chandrasekaran V, Grocott-Mason R, Elwidaa H, Mazhar R, Khaghani A, Mitchell A, Ilsley C, Yacoub M H

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

Allografts offer many advantages over prosthetic valves, but allograft durability varies considerably.

METHODS

From 1969 through 1993, 618 patients aged 15 to 84 years underwent their first aortic valve replacement with an aortic allograft. Concomitant surgery included aortic root tailoring (n = 58), replacement or tailoring of the ascending aorta (n = 56), and coronary artery bypass grafting (n = 87). Allograft implantation was done by means of a "freehand" subcoronary technique (n = 551) or total root replacement (n = 67). The allografts were antibiotic sterilized (n = 479), cryopreserved (n = 12), or viable (unprocessed, harvested from brain-dead multiorgan donors or heart transplant recipients, n = 127). Maximum follow-up was 27.1 years.

RESULTS

Thirty-day mortality was 5.0%, and crude survival was 67% and 35% at 10 and 20 years. Ten- and 20-year rates of freedom from complications were as follows: endocarditis, 93% and 89%; primary tissue failure, 62% and 18%; and redo aortic valve replacement, 81% and 35%. Multivariable Cox analyses identified several valve- and procedure-related determinants: rising allograft donor age and antibiotic-sterilized allograft for mortality; donor more than 10 years older than patient for endocarditis; rising donor age minus patient age, rising implantation time (from harvest to aortic valve replacement), and donor age more than 65 years for tissue failure; and rising donor age minus patient age, young patient age, rising implantation time, and subcoronary implantation preceded by aortic root tailoring for redo aortic valve replacement. Estimated 10- and 20-year rates of freedom from tissue failure for a 70-year-old patient with a viable valve from a 30-year-old donor and no other risk factors were 91% and 64%; the figures were 71% and 20% if the donor age was 65 years. The rates of freedom from tissue failure for a 30-year-old patient with a 30-year-old donor were 82% and 39%; the figures were 49% and 3% with a 65-year-old donor. Beneficial influences of a viable valve were largely covered by short harvest time (no delay for allografts from brain dead organ donors or heart transplant recipients) and short implantation time.

CONCLUSIONS

Primary allograft aortic valve replacement can give acceptable results for up to 25 years. The late results can be improved by the use of a viable allograft, by matching patient and donor age, and by more liberal use of free root replacement with re-implantation of the coronary arteries rather than tailoring the root to accommodate a subcoronary implantation.

Для цитирования: Lund O, Chandrasekaran V, Grocott-Mason R, Elwidaa H, Mazhar R, Khaghani A, Mitchell A, Ilsley C, Yacoub M H. Primary aortic valve replacement with allografts over twenty-five years: valve-related and procedure-related determinants of outcome.. The Journal of thoracic and cardiovascular surgery. 1999. DOI: 10.1016/s0022-5223(99)70471-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.