DOI 10.1371/journal.pone.0351819
Riboflavin-sensitized UVA collagen crosslinking produced a controllable, dose-dependent increase in the nanomechanical strength of ex vivo bovine dura mater.
Аннотация
BACKGROUND
Dural defects, either from trauma, tumor resection, surgical approaches, genetics, or spontaneously represent a significant clinical challenge in neurosurgery. Given the established efficacy of riboflavin-sensitized ultraviolet-A (UVA) photo-crosslinking in ophthalmology, this study investigated its feasibility and dose-response characteristics as a novel strategy to biochemically augment the mechanical integrity and strength of ex-vivo bovine dura mater.
METHODS
Forty bovine dura mater specimens were treated ex vivo using riboflavin concentrations of 2, 4, or 8 mM combined with UVA irradiation at 0.3 or 3 mW/cm2. PBS-treated specimens exposed to UVA served as controls. Atomic force microscopy nanoindentation was used to measure the local elastic modulus in matched regions before and after treatment, enabling paired assessment of treatment-induced mechanical changes while minimizing inter-sample variability. Post-treatment stiffness, fold-change from baseline, and riboflavin dose-response relationships were analyzed statistically.
RESULTS
Baseline elastic moduli were equivalent across all groups (mean approximately 52 kPa, p = 0.92). While UVA alone caused a modest approximately 2- to 3-fold stiffness increase, riboflavin-UVA treatment produced a dramatic, concentration-dependent effect. The highest treatment (8 mM RF, 3 mW/cm2 UVA) increased the elastic modulus 150-fold, from approximately 53 kPa to approximately 8,000 kPa. Post-UV stiffness exhibited a strong linear relationship with riboflavin concentration (R2 = 0.994), indicating a precisely titratable crosslinking effect. All treatment conditions were statistically distinguishable (p < 0.001).
CONCLUSION
Riboflavin-sensitized UVA crosslinking substantially increases the nanomechanical strength of ex vivo bovine dura mater in a controllable, dose-dependent manner. These findings establish a proof of concept for biochemical reinforcement of dural tissue that might be used clinically. As a next step evaluation using human dura, macroscopic biomechanical testing, penetration-depth analysis, and safety assessment is warranted.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.