Clinical implementation of intensity modulated proton therapy in breath-hold for mediastinal lymphoma patients using surface monitoring and nasal high-flow therapy.

Vilches-Freixas Gloria, van der Klugt Kim, Canters Richard, Kneepkens Esther, Vereijken Fleur, Cobben Maud, van den Bosch Maud, Lubken Indra, van Engelen Anne, Stultiens Cissy, Velders Marije, Cartechini Giorgio, Unipan Mirko, Berbée Maaike, Ta Bastiaan

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: We report our first clinical experience treating mediastinal lymphoma patients in breath-hold (BH) with intensity modulated proton therapy (IMPT), using optical surface scanning (OSS) for beam gating and nasal high-flow therapy (NHFT). Moreover, we evaluated BH stability throughout treatment and assessed adequacy of applied treatment margins.

MATERIALS AND

METHODS

Thirteen patients received IMPT-BH with anterior beams supported by NHFT and OSS. OSS enabled gated treatment delivery with a 3 mm breathing window and a maximum isocenter shift of 5 mm. OSS respiratory traces were synchronized with machine log-file beam delivery data to identify beam-on periods. BH stability, BH duration, and OSS-derived isocenter shifts were assessed during cone beam CT (CBCT) and treatment. Margin adequacy was evaluated using post-treatment CBCTs acquired for 34 fractions (2-3 CBCTs per patient), while plan robustness over time was assessed with weekly repeat-CTs.

RESULTS

Analyzing 187 fractions, the median number of BHs was 1 [1-6] per CBCT and 5 [3-20] per treatment delivery. Intra- and inter-BH surface stability were within 1 mm, and the median isocenter deviation during beam delivery was less than 3 mm. Average fraction time was 44 ± 13 min, decreasing as patients became more experienced. One plan adaptation was required in the entire cohort. Residual target shifts during BH treatments were < 8 mm, comparable to motion in free-breathing.

CONCLUSIONS

IMPT-BH with OSS and NHFT is feasible for treating mediastinal lymphoma, providing stable BHs, and acceptable treatment times. Interfraction motion was slightly higher than intrafraction motion, suggesting that combining bone alignment with soft tissue adjustment could improve setup accuracy.

Для цитирования: Vilches-Freixas Gloria, van der Klugt Kim, Canters Richard, Kneepkens Esther, Vereijken Fleur, Cobben Maud, van den Bosch Maud, Lubken Indra, van Engelen Anne, Stultiens Cissy, Velders Marije, Cartechini Giorgio, Unipan Mirko, Berbée Maaike, Ta Bastiaan. Clinical implementation of intensity modulated proton therapy in breath-hold for mediastinal lymphoma patients using surface monitoring and nasal high-flow therapy.. Physics and imaging in radiation oncology. 2026. DOI: 10.1016/j.phro.2026.101071.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.