MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1298/ptr.26-e00013

Медицинская библиотека · Physical therapy research · 2026

Intra- and Inter-examiner Reliability of Diaphragmatic Ultrasound Parameters in People with Stable Chronic Obstructive Pulmonary Disease.

Tanaka Takako, Wu Kenneth, Yanagita Yorihide, Morishita Tatsuya, Toyama Shusuke, Nagata Fumiya, Shingai Kazuya, Ikeuchi Tomoyuki, Mori Kentaro, Suyama Kazuaki, Mathur Sunita, Kozu Ryo

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to evaluate the intra- and inter-examiner reliability of ultrasound-derived diaphragm thickness (Tdi) and diaphragmatic excursion (DE) in individuals with chronic obstructive pulmonary disease (COPD).

METHODS

This prospective cross-sectional study included outpatients with stable COPD. Six participants were analyzed for intra-examiner reliability and 16 for inter-examiner reliability. Two trained examiners performed diaphragmatic ultrasound using a same-day standardized protocol. In the intra-examiner phase, 1 examiner performed 2 repeated measurements in 6 participants on the same day. In the inter-examiner phase, 2 examiners performed 2 measurements in 16 participants under the same-day standardized protocol. Tdi was measured at functional residual capacity (FRC), residual volume (RV), and total lung capacity (TLC), and DE was measured from resting expiration to maximal inspiration. Intra-examiner reliability was assessed using intraclass correlation coefficients (ICCs; ICC [1,1]), and inter-examiner reliability was evaluated using ICC (2,1); standard error of measurement and minimal detectable change were also calculated.

RESULTS

Intra-examiner ICCs ranged from 0.70 to 0.98. Tdi at TLC (TdiTLC) and DE demonstrated high intra-examiner reliability (ICCs ≥0.83 for both examiners). Inter-examiner analysis showed high agreement for TdiTLC and DE (ICCs = 0.83 and 0.88, respectively), whereas Tdi at FRC and RV showed moderate agreement (ICCs = 0.57 and 0.59, respectively).

CONCLUSIONS

Ultrasound-derived diaphragm parameters-particularly TdiTLC and DE-demonstrated high intra- and inter-examiner reliability in individuals with stable COPD under a same-day standardized protocol. This suggests the potential clinical utility of diaphragmatic ultrasound for the reliable evaluation and short-term monitoring of diaphragmatic function in clinical and research settings.

Для цитирования: Tanaka Takako, Wu Kenneth, Yanagita Yorihide, Morishita Tatsuya, Toyama Shusuke, Nagata Fumiya, Shingai Kazuya, Ikeuchi Tomoyuki, Mori Kentaro, Suyama Kazuaki, Mathur Sunita, Kozu Ryo. Intra- and Inter-examiner Reliability of Diaphragmatic Ultrasound Parameters in People with Stable Chronic Obstructive Pulmonary Disease.. Physical therapy research. 2026. DOI: 10.1298/ptr.26-e00013.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.