MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4269/ajtmh.1984.33.151

Медицинская библиотека · The American journal of tropical medicine and hygiene · 1984

Detection of yellow fever virus in serum by enzyme immunoassay.

Monath T P, Nystrom R R

СтатьяПеревод в очереди

Аннотация

Yellow fever (YF) virus is present in patient's blood during the acute phase of illness. Virus isolation and identification provide a potential method of early diagnosis, but available techniques are slow and require specialized materials and equipment. An alternative approach is direct detection of YF antigen in serum by means of an enzyme-linked immunosorbent assay (ELISA). An antigen-capture ELISA was developed, which used anti-YF antibodies, immobilized on a solid phase (polystyrene plates), to capture YF virus from serum samples. After addition of the virus-containing sample, anti-YF detecting antibody conjugated to alkaline phosphatase was added to detect viral antigen. Trials with various capture and detecting antibodies in systems employing purified YF 17D virus, led to the selection of: 1) two capture antibodies (pooled human serum containing high titer YF IgM antibodies and a type-specific YF monoclonal antibody), and 2) a detecting antibody conjugate consisting of monoclonal antibody broadly cross-reactive with all flaviviruses, purified by affinity chromatography, and conjugated to alkaline phosphatase. The limit of sensitivity in tests against purified YF 17D virus diluted in buffer or normal human serum was 10(3.0) - 10(3.6) PFU/0.05 ml or 0.007-0.029 microgram viral protein/0.05 ml. Sera obtained at intervals from rhesus and cynomolgus monkeys after infection with a wild YF virus strain were tested. The limit of sensitivity of the assay applied to viremic monkey serum was similar (approximately 3.5 log10PFU/0.05 ml).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Monath T P, Nystrom R R. Detection of yellow fever virus in serum by enzyme immunoassay.. The American journal of tropical medicine and hygiene. 1984. DOI: 10.4269/ajtmh.1984.33.151.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.