m+Medelevator.RU
← Поиск публикаций
Analytical methods : advancing methods and applications · 2026

Carbon dioxide-switchable hydrophilicity-assisted lighter-than-water deep eutectic solvent-based liquid-phase microextraction of triazine herbicides from aqueous samples performed in a narrow tube before GC-FID analysis.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Dada Alaa Anwer Ali, Naseri Abdolhossein, Afshar Mogaddam Mohammad Reza, Farajzadeh Mir Ali

Аннотация

Triazine herbicides are widely used agricultural chemicals with high environmental persistence and potential ecotoxicological hazards, necessitating sensitive, precise, and cost-effective analytical methods for their monitoring in water matrices. In this work, a new carbon dioxide-switchable liquid-phase microextraction technique was introduced, leveraging the reversible hydrophilicity transition of an aromatic amine-based deep eutectic solvent for the efficient extraction of simazine, atrazine, and terbutryn from aqueous samples. The menthol : 4-amino-1-naphthol deep eutectic solvent was selected as the optimal extractant due to its favorable switchable behavior, low viscosity, and strong affinity for triazines through π-π, hydrogen bonding, and hydrophobic interactions. Following CO2-induced phase switching and ultrasonication-assisted coalescence, the final organic phase was directly injected into a gas chromatograph equipped with a flame ionization detector. Under optimum conditions, the proposed method provided acceptable extraction recoveries (66-74%) and high enrichment factors (641-719), with low limits of detection (0.17-0.31 ng mL-1) and satisfactory intra- and inter-day precisions (relative standard deviations ≤7.1%). Linear calibration curves were obtained over a concentration range of 1-500 ng mL-1, with coefficients of determination ≥0.995. The method was successfully validated by analyzing real environmental water samples, including river water, tap water, surface water, groundwater, and dam water, with spiked recoveries ranging from 83% to 106%, confirming its robustness in these samples. The samples were free of the analytes. Notably, the procedure required no additional cleanup or solvent evaporation steps and consumed only 130 µL of a biodegradable, low-toxicity deep eutectic solvent, aligning well with the principles of green analytical chemistry.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты